European Installation - Wells M4200 El Manual Para La Operacion Europea

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

EUROPEAN INSTALLATION INSTRUCTIONS
This manual has been prepared for personnel authorized, qualified, certified and licensed to install
electrical equipment, who should perform the initial startup and adjustments covered in this manual.
Make sure incoming voltage matches the appliance rating. A data plate specifying rated voltage,
frequency, phase and wattage is attached to the appliance.
An approved all pole power disconnect switch, with at least 3mm contact gap, must be supplied
and installed in the fixed wiring an accessible location (close proximity to the appliance) by a
licensed electrician.
SUPPLY CORDS
Supply cords, supplied by the installer, shall be oil-resistant, sheathed flexible cable not lighter
than ordinary polychloroprene or other elastic-sheathed cord (code designation 245 IEC 57)
or an approved metallic conduit connection.
Supply power wire length must not exceed 2m length between the point where the cord enters the
appliance and the entry to the outlet box.
ELECTRICAL HOOK-UP
Remove terminal block access panel marked
"NOTICE – REMOVE THIS PANEL FOR TERMINAL BLOCK"
located at right side of appliance.
Connect conduit strain relief to the power supply inlet hole located
on rear enclosure panel.
Thread supply leads through strain relief and connect power leads
to terminals marked "L1", L2", L3", and the neutral lead to terminal
marked "N"
Connect ground lead (green w/yellow stripe) to ground lug
marked "
".
Locate equal potential grounding screw on rear enclosure
marked "
". Secure an appropriate grounding wire to screw.
ELECTRICAL RATINGS
MODEL
M4200-3SEU
308-415 VAC 3ø
VOLTAGE
WATTAGE
3NAC
8750 W
AMPERAGE
L1
L2
11.7
11.7
4
SUPPLY LINE 1
SUPPLY LINE 2
SUPPLY LINE 3
NEUTRAL
GROUND
L3
N
11.7
1.0
L1
L2
L3
N