EUROPEAN INSTALLATION INSTRUCTIONS
•
This manual has been prepared for personnel authorized, qualified, certified and licensed to install
electrical equipment, who should perform the initial startup and adjustments covered in this manual.
•
Make sure incoming voltage matches the appliance rating. A data plate specifying rated voltage,
frequency, phase and wattage is attached to the appliance.
•
An approved all pole power disconnect switch, with at least 3mm contact gap, must be supplied
and installed in the fixed wiring an accessible location (close proximity to the appliance) by a
licensed electrician.
SUPPLY CORDS
•
Supply cords, supplied by the installer, shall be oil-resistant, sheathed flexible cable not lighter
than ordinary polychloroprene or other elastic-sheathed cord (code designation 245 IEC 57)
or an approved metallic conduit connection.
•
Supply power wire length must not exceed 2m length between the point where the cord enters the
appliance and the entry to the outlet box.
ELECTRICAL HOOK-UP
•
Remove terminal block access panel marked
"NOTICE – REMOVE THIS PANEL FOR TERMINAL BLOCK"
located at right side of appliance.
•
Connect conduit strain relief to the power supply inlet hole located
on rear enclosure panel.
•
Thread supply leads through strain relief and connect power leads
to terminals marked "L1", L2", L3", and the neutral lead to terminal
marked "N"
•
Connect ground lead (green w/yellow stripe) to ground lug
marked "
".
•
Locate equal potential grounding screw on rear enclosure
marked "
". Secure an appropriate grounding wire to screw.
ELECTRICAL RATINGS
MODEL
M4200-3SEU
308-415 VAC 3ø
VOLTAGE
WATTAGE
3NAC
8750 W
AMPERAGE
L1
L2
11.7
11.7
4
SUPPLY LINE 1
SUPPLY LINE 2
SUPPLY LINE 3
NEUTRAL
GROUND
L3
N
11.7
1.0
L1
L2
L3
N