DETAILED COMPONENTS
1. Flue cover (back)
2. Inner pipe
3. Flue cover (front)
4. Fireplace assembly with glass door
5. Floor plate
6. Ash box
7. Fire grate
8. Anti-scratch cloth for cleaning the appliance
9. Heat resistant glove
10. Ceiling bracket
11. Tool to manage registers, grill and ash box
12. Envelope containing User and installation instructions and appliance guarantee
13. Bag of screws to fix the pipe cover and ceiling bracket
14. Can of touch up paint
15. Indoor Heat-resistant panels
16. Defelxed panels (2 pieces of "vermiculite")
B:
DIAGRAMS AND SIZE
C:
ASSEMBLY PICTURES
D:
TECHNICAL CHARACTERISTICS
Parameter
Minimum-maximum flue draught
Fire type
Fuel consumption
Flue gas Mass Flow
Nominal efficiency
Nominal output
CO concentration at 13% O2
Nominal fuel load (test)
Re-fuel load (test)
Average flue draught (test)
Net weight
Maximum fuel load
1. INSTALLATION GUIDE
ALL LOCAL REGULATIONS, INCLUDING THOSE REFERING TO NATIONAL AND EUROPEAN
STANDARDS NEED TO BE CXOMPLIED WITH WHEN INSTALLING THE APPLIANCE.
1.1. Fireplace room. The appliance contains ash box, fire grate and glass door. All can be
removed to aid transport and installation.
1.2. Smokes exit. This appliance requires a chimney to exhaust the smoke to the outside. The
diameter of this flue must be the same diameter as the outlet from the appliance. The height of the
chimney must be greater than 4meters from the top of the appliance to the termination. Installation
must comply with all regulations and the flue system must not be shared with another appliance.
1.3. Floor. The floor must be of suitable load bearing capacity for assembly and installation. Weak
floors can be strengthened with a panel to disperse the weight over a larger area.
1.4. Insulation and safety distances. It is advisable to insulate the wall behind the chimney and
the recess (walls floor and ceiling) into which the fireplace will be installed. These structures must
not contain any combustible material (textile, electronic, wood, glass, paper wall etc.) and the
clearance for the appliance to combustible materials must not be less than 600 mm from the back
of the appliance, 250 mm must be respected in the roof. All combustible items (furniture, Hi-fi, DVD
player, TV or carpets) must have a minimum clearance of 1000 mm from the front of appliance.
1.5 Ventilation. Permanent ventilation is required in the room housing the appliance. You must
consider other ventilation devices (air conditioning, fans or heating) that may work simultaneously.
Value
11-13 Pa
Intermitente
5 Kg./h
11 g/s
82 %
15.5 Kw.
0.12 %
3.4 Kg.
45 min.
11.5 PA
217 Kg.
5 Kg.
Página 14 de 25