The air going out must be balanced with air coming in. If necessary install an 80mm diameter inlet
in the room
The regulations in the UK require there to be purpose provided ventilation of 550mm2 per kW of
heat output over 5kW.
1.6. Type of fireplace. This is a free standing appliance and must not be enclosed or covered by
any material.
1.7. Appliance assembly.
1.7.1. Floor plate
(1).
in mind the flue connection. Below this you can locate the outside air
JUST FOLLOW THIS SECTION IF YOU MAKE THE OUTSIDE AIR INLET (If not, continue the
installation in paragraph 1.7.3.)
1.7.2. Outside air. If you make the outside air, follow the steps framed in red. The air inlet can be done to
the wall or floor:
THE WALL
Perform AFFIXED on the wall where the fireplace, a hole for the outside air (C-2).
-
Place your foot on the platform usually fit into the holes you'll find (C-3).
-
Connect the ring inlet of air down plate (C-4).
-
Connect the hose length of 100 mm supplied and secure with clamps. The second ring connection to
-
the piece screw-diffusing sheet (C-5).
Place the body over the foot of the chimney.
-
Connect the flexible pipe section connecting the ring-diffusing sheet (C-6).
-
Screw-diffuser plate to the bottom of the stack base (C-7).
-
FLOOR
Place your foot on the platform usually fit into the holes you'll find (C-3).
-
Connect the ring inlet of air down plate (C-4).
-
Connect the hose length of 100 mm supplied and secure with clamps. The second ring connection to
-
the piece screw-diffusing sheet (C-5).
Place the body over the foot of the chimney.
-
-
Connect the flexible pipe section connecting the ring-diffusing sheet (C-6).
-
Screw-diffuser plate to the bottom of the stack base (C-7).
1.7.3. Stand assembly
1.7.4. Fixing and level the appliance. Put the appliance on the stand. Next put the screw like a
picture
and level the appliance, using this screw.
(10)
1.7.5. Installation of cover pipe (back) and ceiling bracket (back)
necessary you can cut the flue pipe to the height of the room) and the back ceiling bracket.
1.7.6. Installation of inner pipe
improve performance. The neck is attached to the smoke outlet pipe with two screws.
1.7.7. Installation of flue pipe
1.7.8. Installation of cover pipe (front)
of the room.
1.7.9. Installation the ceiling bracket (front). Finally, fix the ceiling bracket to the roof using the
plugs and screws provided.
1.8. Heat-resistant panels. These panels are set into a box and they are black on one side,
without colouring on the other. In this way, the colour wanted can be chosen. Follow the steps to
install properly.
1.8.1. Heat resistant panels assembly
the other 4 pieces. Finally put the ash box and the fire grate in middle of base.
1.9. Deflexed Panels assembly. These pieces are "vermiculite" and place in the sides socket.
First put the top pieces (the smallest)
previous piece (bigger)
1.10. Access for cleaning and security. It is possible to sweep the appliance and flue from inside
the appliance.
2. USER'S GUIDE
Position the Floor plate where the appliance is going to be installed; bearing
Place the stand on the floor plate and fitting it into the slits in.
(8-9).
(11-12-13).
After placing the inner tube section, we place the flue pipe .
(14-15).
(16).
(17-18).
(19).
(20).
The fireplace comes with a section of inner tube to
This pieces, if is necessary, you can cut to the height
First put the sides panels (one on each side) then
Then place the bottom piece in the lace beneath the
Fit the back piece (if it is
(5-6).
Página 15 de 25