Adjust screen brightness
Activating/Triggering external devices (if installed)
TECHNICAL PRECAUTIONS
Cleaning:
• Clean all units with a soft cloth and gentle cleaner. Do not spray cleaner directly on unit. Do not use an abrasive cleaner or cloth.
Wiring:
• When a short is detected between the door station and the expansion monitor station, the expansion monitor station stops functioning
and the Status LED flashes rapidly until the short is removed. The master monitor station does not indicate the short and stops its
operation with the door station. Check the wires.
• When a short is detected between the expansion monitor station and the master monitor station, the master monitor station stops functioning
and the Status LED flashes rapidly until the short is removed. The expansion monitor station operates with the door station normally.
• If noise is heard from the expansion monitor station, the wiring is disconnected between the video door station and the expansion monitor
station.
• If noise is heard from the master monitor station, the wiring is disconnected between the video door station and expansion monitor station or
between the master monitor station and the expansion monitor station.
Trouble:
• If the station does not respond, reboot this station by pressing the RESET button.
• When the power supply is turned off, power failure, or the RESET button is pressed, the setting of brightness, communication volume,
and call tone volume are returned to the default setting.
SPECIFICATIONS
jO-1FD (Expansion monitor station)
Power supply
DC 18V (from power supply)
Current consumption (standby) 38mA (max) 420mA
Communication
Hands-free: Auto-voice actuation
PTT: Press-to-talk, release to listen
Ambient temperature 0 - 40°C (+32°F - +104°F)
Monitor
7 inch color LCD screen
Mounting
Wall-mount
1
Push
when the screen is difficult to see. The screen brightness
changes from [
1] (the darkest) to [
communication or monitoring.
NOTES:
• The current brightness level is displayed on the screen and
disappears in approx. 5 seconds.
• The default setting is [
1
Press
to operate to the unit's option output.
NOTES:
• Optional devices must be installed and connected properly.
The
can control lights, secondary doors, garages, etc.
• While the
button is pressed, the N/O dry closure contact
signal is kept being output.
Electrical box
3-gang box
Material
Flame resistant ABS resin
Color
White
Dimension
130 (H) x 230 (W) x 21 (D) (mm)
5-1/8 (H) x 9-1/16 (W) x 13/16 (D) (inches)
Weight
Approx. 480g (1.06 lbs.)