Use a second coax cable and connect one end to the
mating port of the first coax cable on the 75 ohm
grounding block and run the other end into your home
and connect to the Power Inserter. The 75 ohm
grounding block needs to be placed as close as
possible to the point where the second coax cable enters
your home
NOTE: Leave enough slack in the coax cable to create a drip loop
so that moisture cannot enter the house. You will also need to seal
the coax cable entry point into your house with an exterior caulk.
c) Ground the 75 OHM Grounding Block: Connect a #8
aluminum or #10 grounding wire to a screw terminal
provided on the 75 ohm grounding block. Connect the other
end of the wire to an acceptable building ground location.
Refer to Step a) in this section for acceptable building
grounding locations.
Be sure to double check all your connections after your
installation is complete. Ensure there are good electrical
connections of your grounding wires and coax cables.
See Fig. 2 below for an example of a properly grounded
antenna installation.
If you are unsure how to properly ground your antenna
installation, contact a professional installer in your area.