Important - ROBLIN Inspiration 2770 Instrucciones De Instalación E Utilización

Campana
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
or injury and would deem the manufacturers guarantee null and void.
IMPORTANT - The wires in this mains lead are coloured in accordance with the following code :
green / yellow : earth
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured
markings identifying the terminals in your plug, proceed as follows.
-
The wire which is coloured green and yellow must be connected to the terminal in the plug which is
marked with the letter E or by the earth symbol
-
The wire which is coloured blue must be connected to the terminal which is marked with the letter N
or coloured black.
-
The wire which is coloured brown must be connected to the terminal which is marked with the letter
L or coloured red.
ATTENTION: Do not forget to use adequate plugs to the support brackets. Enquire after the manu-
facturers. Do an embedding if necessary. The manufacturer accepts no responsibility in case of a
faulty hanging due to the drilling and the setting up of plugs in the ceiling.
It is necessary to provide an adequate thermal isolation in case the blower is placed in particularly
cold rooms.
• The Hood can be fitted onto the lower surface of the wall furniture. (650 mm min. from the surface of the
cooking appliance to the underside of the cooker hood.)
• To carry out a cutting (embedding) on the lower surface of the wall furniture, as indicated.
• To drill the outlet onto the top or the back of the wall furniture.
• To fix the 2 squares using the provided screws.
• To place the anti-backflowflats item 9 over the round outlet. To secure the connections with appropriate
clamping rings or adhesive tape.
• To place the hood into the embedding and fit it on the 2 squares using the 4 screws supplied.
• DUCTING
The hood is more effective when used in the extraction mode (ducted to the outside). When the cooker
hood is ducted to the outside, charcoal filters are not required.
The ducting used must be 150 mm (6 INS), rigid circular pipe and must be manufactured from fire retard-
ant material, produced to BS.476 or DIN 4102-B1. Wherever possible utilise rigid circular pipe which has
a smooth interior, rather than the expanding concertina type ducting.
Maximum length of ducting run:
- 4 metres with 1 x 90° bend.
- 3 metres with 2 x 90° bends.
- 2 metres with 3 x 90° bends.
The above assumes our 150 mm (6 INS) ducting is being installed. Please note ducting components and
ducting kits are optional accessories and have to be ordered, they are not automatically supplied with the
chimney hood.
- In the extraction mode:
• To connect the round outlet of the hood via a rigid or flexible duct of ø 150 mm.
• To secure the connections with appropriate clamping rings or adhesive tape not provided.
• To remove the possible charcoal filte.
- In the recirculation mode: The filtered air is evacuated in kitchen through an outlet placed on the top of
furniture or the hood.
• To drill a hole of ø 155 mm on the top of furniture.
• To connect the round outlet of the hood via a rigid or flexible duct of ø 150 mm to the outlet on the top of
blue : neutral
brown : live
or coloured green or green and yellow.
GB
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Inspiration 520

Tabla de contenido