Xylem LOWARA Q-Smart Manual De Instalación, Funcionamiento Y Mantenimiento página 43

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 118
(c30=1)
PROGRAMMING DIGITAL INPUTS
(refer to figures
7
and 9)
r34
Setting the
1= NC,
logic of the
Normally
digital input
closed
float switch
2= NO,
G1
Normally
open
r35
Setting the
1= NC,
logic of the
Normally
digital input
closed
float switch
2= NO,
G2
Normally
open
r36
Setting the
1= NC,
logic of the
Normally
digital input
closed
float switch
2= NO,
G MAX
Normally
open
t36
Delay time
0 to 200
until activa-
tion of digital
input float
switch G
MAX (r36)
r37
Setting the
1= NC,
logic of the
Normally
digital input
closed
float switch
2= NO,
G MIN
Normally
open
t37
Delay time
0 to 200
until activa-
tion of digital
input float
switch G
MIN (r37)
c38
Configura-
0= Not
tion of pro-
used.
grammable
1= External
digital input
command
D IN_PROG
and the
(1)
pumps are
switched on
one at a
time (2 sec-
onds apart).
2= External
alarm
3= External
ON/OFF.
4= Change
set point
r38
Setting the
1= NC,
logic of pro-
Normally
grammable
closed
digital input
2= NO,
D IN_PROG
Normally
open
t38
Delay time
0 to 200
until activa-
-
2
-
2
-
2
sec
0
-
2
sec
0
-
0
-
2
sec
0
tion of pro-
grammable
digital input
D IN_PROG
(r38)
6CP Q-SMART MODULE (OPTION ACCESSO-
RY),
It is an electronic card with six relays and voltage-
free contacts (refer to figures 7, 9).
c40
Configura-
0= Disabled
tion of
1= P1 run-
OUT_1
ning
relay (K3 on
2= P2 run-
board)
ning
3= Fuse 1
burned
4= Fuse 2
burned
5= High
level alarm
6= Alarm
Max level
threshold
7= Alarm
Minimum
level thresh-
old
8= External
alarm
9= Auto-test
in progress.
10= Alarm
sensor fault
11= Power
ON
12=Aut/Man
mode
c41
Configura-
See configu-
tion of
ration c40
OUT_2
relay (K4 on
board)
c42
Configura-
See configu-
tion of
ration c40
OUT_3
relay (K5 on
board)
c43
Configura-
See configu-
tion of
ration c40
OUT_4
relay (K6 on
board)
c44
Configura-
See configu-
tion of
ration c40
OUT_5
relay (K7 on
board)
c45
Configura-
See configu-
tion of
ration c40
OUT_6
relay (K8 on
board)
en - Original instructions
-
0
-
0
-
0
-
0
-
0
-
0
43

Publicidad

Tabla de contenido
loading

Tabla de contenido