Fanaway LED EVO1 Installation Instructions
This is not a product fault and as such is not covered under warranty.
NOTE: Some dimmers have a minimum load of 20W. Before turning on the LED downlight, ensure the dimmer
position is on the maximum setting.
NOTE: A licensed electrician is required to hardwire/install a local dimmer/switch to the LED light fitting.
Reverse function
Your ceiling fan can operate either in fan mode or reverse fan mode.
SUMMER Mode: The reverse switch shall be in the "LEFT" (SUMMER) position to make the fan rotate in an
anticlockwise direction. The airflow will be directed downwards, for cooling in summer.
WINTER Mode: The reverse switch shall be in the "RIGHT" (WINTER) position to make the fan rotate in a clockwise
direction. The airflow will be directed upwards, for energy conservation in winter.
WOBBLE:
The fan blades have been adjusted in the factory to minimize any wobble.
NOTE: CEILING FANS TEND TO MOVE DURING OPERATION DUE TO THE FACT THAT THEY ARE MOUNTED ON
A RUBBER GROMMET. IF THE FAN WAS MOUNTED RIGIDLY TO THE CEILING IT WOULD CAUSE EXCESSIVE
VIBRATION. MOVEMENT OF A FEW CENTIMETRES IS QUITE ACCEPTABLE AND DOES NOT SUGGEST ANY
PROBLEM.
TO REDUCE THE FAN WOBBLE: PLEASE CHECK THAT ALL SCREWS WHICH SECURED THE MOUNTING
BRACKET AND DOWN ROD ARE SECURE.
BALANCING A WOBBLING CEILING FAN:
For your convenience, a Balancing Kit is included; please follow this procedure when balancing the fan:
1)
Install fan without light dome before balancing the fan.
2)
Define the base plate into four areas (point A, B, C & D). Use one
weight from the balance kit to lightly stick on the edge of the base
plate (say point A), if the wobble worsens, then take off the balance
kit and lightly stick it on the opposite side (say point B); if the
wobble is worse, then go to the adjacent point C or D, if the wobble
gets better, then securely stick on the weight at this location on the
base plate.
3)
After balancing the fan, assemble the light dome to the light base.
NOISE:
When it is quiet (especially at night) you may hear occasional small noises. Slight power fluctuations and frequency
signals superimposed in the electricity for off-peak hot water control, may cause a change in fan motor noise. This is
normal. Please allow a 24-hour "breaking -in" period, most noises associated with a new fan disappear during the time.
The manufacturer's warranty covers actual faults that may develop and NOT minor complaints such as hearing the
motor run – All electric motors are audible to some extent.
10 | P a g e
AFTER INSTALLATION
V e r 1 . 0