Start, Stop, Direction and Speed Control
Factory default parameter values allow the drive to be controlled from
the integral keypad. No programming is required to start, stop, change
direction and control speed directly from the integral keypad.
To change the speed reference of an IP66, NEMA/UL Type 4X rated
drive, access parameter A069 [Internal Freq] and press Enter or Sel to
enter program mode. Use the Up Arrow or Down Arrow key to adjust the
speed reference. Press the Enter key to save the new value.
Important: To disable reverse operation, see A095 [Reverse Disable].
If a fault appears on power up, refer to page 20 for an explanation of the
fault code. For complete troubleshooting information, refer to the
PowerFlex 40 User Manual on the CD supplied with the drive.