Battery Replacement - GYS GYSPACK 750 Manual Del Usuario

Ocultar thumbs Ver también para GYSPACK 750:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
Translation of the original instructions

BATTERY REPLACEMENT

2
1
Product
Battery
GYSPACK 750
6-SPB-25
To replace the battery :
The booster must be disconnected form the power supply.
First the back panel must be unscrewed (19 screws) and removed.
Once the back panel is removed, the battery front appears (cf illustration). Remove the positioning belt 1 .
The battery is connected to the GYSPACK at two points : at the - terminal 3 and at the + terminal 2 . To
remove the battery, remove the 2 screws that enable the connection between the battery and the GYSPACK at
the terminals + and -.
When putting a new battery, make sure to observe the polarities of both the battery and the
GYSPACK 750. Terminal - on the left, terminal + on the right (cf illustration). Put the 2 screws
and washers back, tighten the nuts (recommended torque wrench 4 N.m).
Place the booster's backpanel screws back on.
GYSPACK 750
Type
Voltage (V)
Lead- acid battery
12
Dimensions
Capacity (Ah)
(cm)
26
36 x 20 x 43
EN
3
Battery ref
53140
13