ENGLISH
This manual is for use by qualified personnel and contains information and tips to use and keep your coffee maker as efficiently as
possible.
Please read all instructions very carefully before you actually use your machine to make sure the machine works properly and to
ensure a long working life. Instructions are part of the product. Please keep this document.
mod. TREVISO – TREVISO LX – TREVISO LX 1500W
Semi-automatic with continual dispensing managed by a level controller through a microswitch located on the dispensing group
head lever. Available in the versions 1 group with vibration pump and 1 group with rotary pump. Available in the TREVISO 1 filter
head version with vibration pump, the TREVISO LX 1 filter head version with rotary pump and the TREVISO LX 1500W 1 filter head
version with rotary pump, 1.8 litre boiler and 1500W heating element.
WIDTH
DEPTH
HEIGHT
BOILER CAPACITY mod. TREVISO – TREVISO LX
BOILER CAPACITY mod. TREVISO LX 1500W
TANK CAPACITY
TANK CAPACITY (Version with vibration pump)
VOLTAGE
HEATING ELEMENT INPUT mod. TREVISO – TREVISO LX
HEATING ELEMENT INPUT mod. TREVISO LX 1500W
ELECTRIC VIBRATION PUMP INPUT
ROTARY ELECTRIC PUMP INPUT
SOLENOID VALVE INPUT
AUTOM. LEVEL CONTROLLER INPUT
BOILER WORKING PRESSURE
SAFETY VALVE CALIBRATION PRESSURE
EXCHANGER SAFETY VALVE CALIBRATION PRESSURE
MAINS WATER PRESSURE (MAX) TREVISO LX – TREVISO LX 1500W
COFFEE DELIVERY PRESSURE
The weighted sound pressure level A of the coffee maker is less than 70dB.
For correct appliance operation and trouble-free maintenance, please read this booklet carefully and comply with the instructions and
rules, also referring to the diagrams given in it.
Before installing the appliance ensure that the mains voltage and power correspond to the data given in the technical details table.
Take the appliance out of the packaging and put it in its final place of installation ensuring that it is stable and safe and that there is
the necessary space for using it. Place the machine in a way that the distance between the grid and the floor is wider than 1,5 mt.
Electrical connection
Before connecting the power cable, follow the instructions below to install a safety switch and of the proper capacity:
Install ground cable, then phase cables. Uninstall phase cables first and then ground if needed.
Make sure the ground connection complies with existing standards and regulations.
N.B. CHECK THAT THE DATA ON THE RATING PLATE CORRESPOND TO YOUR MAINS ELECTRICITY SUPPLY.
Water connection
1)
Only cold water must be supplied to the appliances.
2)
In the TREVISO version (Vibration pump) take out the container, rinse it, fill it and put it back in place, reinserting the tubes, and
replace the cap.
TECHNICAL DETAILS
(1,1-1,3 Bar) MPa
(1.8 Bar) MPa
(12 Bar) MPa
(8-9 Bar) MPa
INSTALLATION
16
mm
322
mm
460
mm
451
litres
1,052
litres
litres
litri
V
120/230
kW
kW
kW
0,041/120V - 0,048/230V
kW
0.12
kW
0,01
kW
0,01
0,11 – 0,13
0,18
(6 Bar) MPa
0,8/0,9
1,8
3,4
3.4
1,3
1,5
1,2
0,6