NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
TO STOP HEATER
1. Turn switch to "OFF" and unplug power cord.
TO RESTART HEATER
1.Wait 10 seconds after stopping heater.
2. Repeat steps under to start heater.
8. LONG TERM STORAGE OF YOUR HEATER
FUEL TANK DRAIN
1. Drain fuel tank through fuel cap opening. (For DFA-45T/70T Models Only)
2. Remove drain plug from rear bottom side of fuel tank by pulling plug grip downward and drain.
(For DFA-125T/170C/210C Models Only. See Figure 10)
3. Using a small amount of kerosene, swirl and rinse the inside of the tank.
NEVER mix water with the kerosene as it will cause rust inside the tank.
Pour the kerosene out making sure that you remove it all.
IMPORTANT : Do not store kerosene over summer months for use during next heating season.
4. Reinstall fuel cap. Properly dispose of old and dirty fuel. (For DFA-45T/70T Models Only)
5. Reinstall Drain Plug as follows. (For DFA-125T/170C/210C Models Only. See Figure 11)
- Insert plug's seal head fully into drain hole so that flange is flush to tank's bottom.
- Insert seal cap fully into head hole so that cap flange is flush to head flange.
Drain Plug
Figure 8
IMPORTANT : Reinstall plug fully into hole in tank, Otherwise it will not seal completely.
6. Store heater in dry well ventilated area. Make sure storage place is free of dust and corrosive fumes.
7. Store the heater in the original box with the original packing material and keep the USER'S MANUAL
with the heater.
Using old fuel could damage heater.
Plug Grip
Rear bottom side
of Fuel Tank
Drain Hole
Fuel Tank
Seal Head
Head Flange
Figure 9
10
Head Flange
Head Hole
Seal Cap
Cap Flange