Setting The Detector; Remote / Self Test (Am Detectors Only); Walk Testing The Detector; Green Mode (Am Detectors Only) - General Electric DD66X Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12

Setting the detector

See Figure 7 for the jumper locations in the detector.
J1: Setting LEDs
On: Enables both LEDs on the detector at all times (factory
default).
Off: Disables both LEDs on the detector at all times.
Removed: Puts both LEDs under the control of the Walk Test and
Day/Night input. This activates the memory feature of the
detector. When the detector is Disarmed and the input Walk Test
is disabled, the microwave section is turned off for DD66X or in
Anti Masking detection for DD66XAM. In this configuration the
detector operates as a PIR only.
J2: Dual loop setting
This sets the alarm and tamper relays. It allows you to connect the
detector to any control panel (see Figures 3 and 6).
SW 1: Polarity setting of the control voltage (CV)
On: Active High. Provides the standard GE Security logic with
"Active High" logic to enable Walk Test (WT), Day/Night (D/N), and
Remote Test inputs (factory default).
Off: Active Low. Provides "Active Low" logic to enable Walk Test
(WT), Day/Night (D/N) and Remote Test inputs.
SW 2: µW only / Dual mode
On: µW only mode. Consequently the PIR circuitry is switched off
and the detector will only signal alarms caused by the microwave
circuitry.
Off: Dual mode. In dual mode the detector signals an alarm when
both technologies (microwave and PIR) have identified a target
moving in the protected area (factory default).
SW 3: Detector range
The microwave can be selected between 20 ± 0.5 m, and
12 ± 0.5 m (65 ft. 7 in. ± 1 ft. 8 in., and 39 ft. 4 in. ± 1 ft. 8 in.).
Note:
Only the microwave range will be reduced, not the PIR
section.
SW 4: Detection coverage
The detection coverage can be selected between 360 degrees for
normal application, and 180 degrees for special applications.
Note:
Only the coverage of the PIR will be adjusted.
SW 5 (AM detectors only): When to signal AM (anti-masking) or
TF (technical fault) output
Note:
Switch 5 has an effect only when J1 (Setting LED) is
removed.
On: Day mode only. Signals AM or TF only when the system is in
Day mode (factory default).
Off: Day/Night mode. Always signals AM or TF during Day and
Night mode.
SW 6 (AM detectors only): AM sensitivity
On: High. Selects High level of AM sensitivity (EN 50131).
Off: Standard. Selects Standard level of AM sensitivity (factory
default).
Advised minimum mounting height for High AM sensitivity is 3 m
(9 ft. 10 in.).
4 of 36
SW 7 (AM detectors only): Resetting the AM/TF output
Note:
Switch 7 has an effect only when J1 (Setting LED) is
removed.
The system will only reset an AM alarm if it has ensured that the
cause of the AM alarm has been removed. If the AM circuitry
cannot return to its original reference levels, then either the
detector is still masked or possibly has been damaged. The owner
should then visually check that the detector is still fully functional.
On: After walktest. After a 40-second inhibit period, resets the AM
or TF status when a (dual) motion alarm is generated.
Off: Authorized reset. Resets the AM or TF status after a (dual)
motion alarm when the system is in Day and Walk Test status. The
yellow LED will turn off and the system is reset (factory default).
SW 8 (AM detectors only): Signalling AM or TF output
On: AM + alarm relay. Signals AM on both the AM and Alarm
relays. Signals TF on the AM relay only (EN 50131).
Off: AM relay only. Signals AM and TF on the AM relay (factory
default).

Remote / self test (AM detectors only)

Remote test: This test allows the DD66XAM to be tested from the
control panel. Use terminal 12 to activate the remote test. The
DD66XAM will activate the Alarm relay if the test result is positive
and the AM relay if the test result is negative.
Self test: The DD66XAM monitors the PIR and microwave circuits
every 6 hours. A defect is reported as a technical fault. After a
successful (dual) motion alarm the time interval between every
self-test will be extended by 6 hours.

Walk testing the detector

The DD66X series provides a walk test mode for testing the
detectors operation and coverage pattern if the detector is set to
LED's disabled. To walk test the detector, remove the supply
voltage and apply it back on. The walk test mode can be started
once the startup sequence has completely finished (LED flashes
for 45 or 60 seconds). The unit stays in walk test mode for
30 minutes. The detector returns to normal operating mode after
the walk test mode times out.

Green mode (AM detectors only)

The detector can be programmed in several ways to minimize the
exposure of microwave radiation to human and animal, although
the detector is already sending microwave signal on a very low
power level.
The detector will switch the microwave section off for 3 minutes
after a dual alarm. The detector is in PIR only during this timer.
Settings option 1
J1: Off
SW 2: Off
Settings option 2
J1: Removed
SW 2: Off
The microwave section is switched off and for DD66XAM is
switched to AM section. The detector operates in PIR mode only.
Setting
J1: Removed
SW 2: Off
System in Armed status
System in Disarmed status
System Walk Test Disabled
P/N 146249999 • REV 3.2 • ISS 17JUN09

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dd669Dd669amDd666-dDd666am-d

Tabla de contenido