2.0 TECHNICAL CHARACTERISTICS
2.1 General rules
Install the pump:
On an horizontal reinforcement (ex: stoking tank) or on the pump shelf
(optional) so that the pump head stays always in vertical position +/-15°.
Far from an hot source in dry places at maximum temperature of 45°C and
minimum 0°C.
In a ventilated place and easily accessible by an operator for periodical
maintenance.
At a suitable height above the chemical up to a maximum height of 1.5
ЦОЭОЫЬ. IП ПШЫ ОбТРОЧМв ШП ЭСО ЩХКЧЭ ТЭ'Ь ЧОМОЬЬКЫв ЭШ ТЧЬЭКХХ ЭСО ЩЮЦЩ ЮЧНОЫ
the level of the chemical, you need to use an injection valve or an anti siphon
valve.
Do not install the pump over the tank in presence of liquids that emanate
fumes unless it is hermetically closed.
2.2 Standard accessories supplied
1 Foot valve / Strainer.
1 Injection fitting / pressure loading valve.
2 meters opaque PE delivery tubing.
2 meters PVC clear suction tubing.
2 meters PVC clear priming tubing
2.3 Electrical characteristics
Power supply: 230 VAC 50/60 HZ
2.4 Electric connection
CAUTION !!!!!
Verify that the earth system is perfectly functional and complies with the applicable
regulations. Ensure the unit is connected to a circuit protected by a highly sensitive
(0.03A) RCCB circuit breaker. If unsure please consult a competent electrician. Verify
that the rated values of the pump are compatible with those of the mains. Never
install the pump directly in parallel with inductive loads (e.g. motors/solenoid valves)
if necessary, use an isolating relay.
There are 2 protection devices inside the pump: a varistor and a fuse.
18/09/15 Rev 3.4
I-Switcher or multi-pole security device
E- Motor or generally inductive charge
14
ENGLISH
P- Metering Pump
R- Relay
A- Supply voltage