Wiring Diagram - Rotex RRHQ011BAV3 Manual De Instalación

Unidad exterior para bomba de calor de aire-agua
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 86
W
IRING DIAGRAM
: Wire clamp
: Terminal strip
: Connector
: Relay connector
: Field wiring
: Protective earth screw
: Noiseless earth
NOTE 1
This wiring diagram only applies to the outdoor unit
NOTE 4
Refer to the option manual for connecting wiring to X6A/X77A
NOTE 5
Refer to the wiring diagram sticker (on back of front panel) on how to use BS1~BS4 and DS1 switch
NOTE 6
Do not operate the unit by short-circuiting protection device S1PH
NOTE 8
Confirm the method of setting the selector switches (DS1) by service manual. Factory setting of all switches: 'OFF'
NOTE 9
Option: Option
Wiring depending on model: Wiring depending on model
A1P~A4P................... Printed circuit board
BS1~BS4................... Push button switch
C1~C4 ....................... Capacitor
DS1 ........................... DIP switch
E1H ........................... Bottom plate heater
E1HC......................... Crankcase heater
F1U~F9U................... Fuse
HAP (A1P)................. Service monitor (green)
HAP (A2P)................. Service monitor (green) (for W1 models only)
H1P~H7P (A1P) ........ Service monitor (orange) (for W1 models only)
H1P~H7P (A2P) ........ Service monitor (orange)
K1M, K2M ................. Magnetic contactor (for W1 models only)
K1R~K4R .................. Magnetic relay
K10R, K11R .............. Magnetic relay (for V3 models only)
L1R~L4R ................... Reactor
M1C........................... Motor (compressor)
M1F ........................... Motor (fan) (upper)
M2F ........................... Motor (fan) (lower)
PS ............................. Switching power supply
Q1DI.......................... Earth leakage circuit breaker (field supply)
R1~R4 ....................... Resistor
R1T ........................... Thermistor (air)
R2T ........................... Thermistor (discharge)
R3T ........................... Thermistor (suction pipe)
Installation manual
16
L
: Live
N
: Neutral
BLK
: Black
BLU
: Blue
BRN
: Brown
GRN
: Green
R4T............................ Thermistor (heat exchanger)
R5T............................ Thermistor (heat exchanger middle)
R6T............................ Thermistor (liquid)
R7T............................ Thermistor (fin) (for W1 models only)
R10T.......................... Thermistor (fin) (for V3 models only)
RC ............................. Signal receiver circuit (for W1 models only)
S1NPH....................... Pressure sensor
S1PH ......................... Pressure switch (high)
TC.............................. Signal transmission circuit (for V3 models
V1R............................ Power module (for V3 models only)
V1R, V2R................... Power module (for W1 models only)
V2R, V3R................... Diode module (for V3 models only)
V3R............................ Diode module (for W1 models only)
V1T ............................ Insulated gate bipolar transistor (for V3 models
X1M ........................... Terminal strip
X1Y............................ Connector
X6A............................ Connector (option)
X77A.......................... Connector
Y1E............................ Expansion valve
Y1S............................ Solenoid valve (4 way valve)
Y3S............................ Solenoid valve (for W1 models only)
Z1C~Z9C ................... Noise filter
Z1F~Z4F.................... Noise filter
ORG
: Orange
RED
: Red
WHT
: White
YLW
: Yellow
only)
only)
RRHQ0011~016BAV3 + RRLQ011~016BAV3+W1
Outdoor unit for air to water heat pump
4PW54248-1

Publicidad

Tabla de contenido
loading

Tabla de contenido