Product Safety Information; Accessory Installation; Product Specifications - Ingersoll Rand 125 Especificaciones Del Producto

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 5

Product Safety Information

Intended Use:
These Air Percussive Needle Scalers are designed for removal of unwanted deposits from metal
and other hardened materials through repetitive application of linear impacts of hardened
needles or a tool steel that is retained and driven by the Scaler. Such deposits include weld
spatter, paint, coatings and other surface materials.
For additional information refer to Air Percussive Tool Product Safety Information Manual
Form 04581450.
Manuals can be downloaded from www.ingersollrandproducts.com.

Accessory Installation

Always use appropriate retainer, latch or sleeve to prevent ejected accessories.
Always turn off the air supply, bleed the air pressure and disconnect the air supply hose
before installing, removing or adjusting any accessory on this tool, or before perform-
ing any maintenance on this tool or any accessory.
To install or remove a Chisel or other accessory, hold the tool by the Casing (18) and
push hard on the Bit Retainer (22).
Prior to Use
Do not lubricate tools with flammable or volatile liquids such as kerosene, diesel or jet
fuel. Use only recommended lubricants.
Use only proper cleaning solvents to clean parts. Use only cleaning solvents which meet
current safety and health standards. Use cleaning solvents in a well ventilated area.
Tools are coated inside and out with rust-resisting oil before leaving the factory. Before using the
tool, remove this oil by dipping the tool in a suitable cleaning solution to wash the oil from the
exterior. Pour about 6 cm
tool for about 15 seconds. Dry the tool immediately after cleaning, pour 3 cm
No. 10 Oil into the air inlet and again operate the tool for 5 seconds to lubricate all working parts.

Product Specifications

Blows per
Models
Minute
125, 125-EU
4,600
† K
= 3dB measurement uncertainty
pA
‡ K
= 3dB measurement uncertainty
wA
* K = Vibration measurement uncertainty
16574113_ed2
WARNING
WARNING
of a clean, suitable, cleaning solution into the air inlet and operate the
3
Stroke
Length
Inch (mm)
† Pressure (L
1-1/8 (28.6)
Sound Level dB(A)
(ISO15744)
)
‡ Power (L
p
96.6
107.6
EN
of Ingersoll Rand
3
Vibration (m/s²)
(ISO28927)
)
Level
*K
w
8.3
1.3
EN-1

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

125-eu

Tabla de contenido