TROUBLESHOOTING HINTS
An easy way to check that the system is working properly, is to disconnect the wiring and test a
terminal (telephone) directly connected to the door panel installation.
Any short-circuit between different terminals of the system will not damage the connected units.
Nothing operates.
Remember that once the power supply is plug in, the system remains inactive for 45 sec,
likewise when connecting any other unit into the installation.
Check the output power supply voltage between ' ' and '+' is among 17,5 to 18,5Vd.c.
Otherwise, disconnect the power supply from the installation and measure again. If its
correct now, it means there is a short circuit in the installation. Disconnect the power supply
from the mains and check the installation.
If after the previous tests, the system is still not working, measure the voltage between 'B' and 'CP'
terminals of the EL520 sound module; if the voltage is different than 12Vd.c., change such
circuit.
If the previous tests are correct, check the self-testing leds (see page 58)
Inappropriate audio level.
Adjust the level volumes as shown on page 59. In case of audio feedback, reduce the volume
until it disappears. If audio feedback disappears only with the adjustments at minimum
positions there could be another problem.
Persistent audio feedback.
Check the BUS is not shortcircuited with another terminal or itself.
The door opening function no operates.
Remember this function is only active during the call and communication processes.
Short-circuit 'CV1' and 'CV2' terminals of the EL520 sound module; then, there must be 12V
(a.c. or d.c. depending on the kind of installed lock release) among the lock release
terminals. If so, check the lock release state.
The system can't be programmed.
Check the switch number 2 of the configuration dip switch is set to ON (see page 63) and that
the programming sequence is correct.
Check on the EL 520 sound modules the self-testing leds (see page 58).
Some units do not receive calls.
Remember there must be only one main unit in each apartment. Check the terminal is
programmed appropriately, and if necessary, repeat the programming steps.
Push buttons do not work.
When pressing the push button, check the door panel emits a confirmation tone; otherwise,
check the push buttons wiring (page 56).
If there is confirmation, check the telephones programming (page 63).
golmar@golmar.es
www.golmar.es
Golmar se reserva el derecho a cualquier modificación sin previo aviso.
Golmar se réserve le droit de toute modification sans préavis.
Golmar reserves the right to make any modifications without prior notice.
–
71