3M Filtrete -30 Guia De Instalacion página 13

Ocultar thumbs Ver también para Filtrete 3M-30:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Step-by-step wiring diagrams
2 Wire Heat GAS MILLIVOLT or 24VAC system
STEP 1 - Connect the R (or RH) wire to the RH terminal. This connects
the heat power.
STEP 2 - Connect the W wire to the W terminal. This connects the heat.
STEP 3 - Set HVAC selections switches to NORMAL and GAS
Your heater is now connected to the 3M-30.
Please Go To Page 6
3 Wire Heat
STEP 1 - Connect the R (or RH) wire to the RH terminal. This connects the heat power.
STEP 2 - Connect the W wire to the W terminal. This connects the heat.
STEP 3 - Connect the G wire to the G terminal on the thermostat. This connects the fan.
STEP 4 - Set HVAC selection switches to NORMAL and:
If you have gas or oil heat, set the HEAT TYPE to GAS
If you have electric heat, set the HEAT TYPE to ELEC
Your system is now connected to the 3M-30.
Please Go To Page 6
RADIO POWER
C H B O W
W Y Y
2
2
HVAC SYSTEM
C
REMOTE POWER
C H B O W
W Y Y
RH RC G A
2
2
Gas Millivolt Heat
C
W
R
RH RC G A
W R G
13
PG

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Filtrete 3m-50

Tabla de contenido