MSA OptimAir 3000 Manual De Operación página 8

Ocultar thumbs Ver también para OptimAir 3000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
USE
Duration and conditions of use
The exhaustion of gas filters is normally detected by odour on the clean side. The
exhaustion of particle filters or the particle filter section of combination filters is
normally signalled by an increase in flow resistance. The minimum volume flow of
the air is no longer maintained and the alarm signal sounds.
When using filters for radioactive substances, micro-organisms or biochemically-
active substances, the particle filter may only be used once!
Volume flow indicator
Battery charge indicator
Battery Minimum Service Time (h)
(Battery fully charged with MSA appropriate charger and new set of filters)
OptimAir 3000
OptiBat
OptiBat E
OptimAir 3000 A
OptiBat
OptiBat E
OptimAir 3000 EX
OptiBat EX
8
=
fault volume flow
=
battery is fully charged
=
battery still has at least 66 % residual capacity
=
battery still has at least 33 % residual capacity
=
battery has less than 33 % residual capacity
battery warning, battery has residual capacity
=
for approx. 15 min. more
battery warning, battery has residual capacity
=
for approx. 1 min. more
=
battery is flat, the apparatus turns off
P3
ABEK
8
8
12
12
4
X
6
X
8
8
OptimAir 3000, 3000A and 3000EX
A
Combination
8
4
12
8
X
X
X
X
8
4
MSA

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Optimair 3000aOptimair 3000ex

Tabla de contenido