In Cab Control Description And Use; The On/Off Function; How To See The Setpoint; Defrost - Zanotti FZ Serie Manual De Uso Y Manutención

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

7.

In cab control description and use

DOWN Button
Scrolls through the menu items Decreases the values.
UP Button
Scrolls through the menu items Increases the values.
ON – OFF Button
Start / Stop the unit
SET Button
Accesses the set point – Accesses the Menus – Confirm the commands
Associated
Led
function
Compressor
Defrosting
Allarm
Fans
Reduced set ON when Reduced set is ACTIVE.
7.1

The On/Off function

At start-up the instrument performs a Lamp Test; the display and LEDs flash for a few seconds to
check that they are working correctly. When it's stopped on the display remain the decimal point led
on.
7.2

How to see the setpoint

To access the Machine Status menu, press the "set" button.
The "Set" folder label appears.
To display the Setpoint value, press the "set" button again. The Setpoint value appears on the display.
To change the Setpoint value, use the "UP" and "DOWN" buttons within 15 seconds.
7.3
Defrost (Optional)
The defrost is automatically managed by the instrument. To activate the defrost cycle manually, press
the "UP" button (if configured =1) for 5 seconds.
ON for compressor on; blinking for delay, delay or enabling
blocked.
ON when defrosting in progress; blinking when activated
manually or with digital input.
ON for active alarm; blinking for silenced alarm.
ON when fan is on.
USE OF LED