Petrarca
Types 62I8 and 62I8/5 are interphones in the Petrarca series for inter-
communicating versions of the 2-wire video kits. It is fitted with 5 push-
buttons; one for door lock release and one for self-start of the interphone
in the system also when it has not been called; 3 pushbuttons can be
added for intercommunicating calls and 2 further pushbuttons for auxilia-
ry services. The interphone can be combined with type 6153/682 for call
volume adjustment and call excluded/door lock open signal.
Connection terminal board
4)
Additional pushbutton common
8)
Auxiliary service 1 (enables activation of relay type 682R).
9)
Self-activation
10)
1st intercommunicating call.
11)
2nd intercommunicating call.
12)
3rd intercommunicating call.
13)
Auxiliary service 2 (enables activation of relay type 682R).
1, 2)
BUS line.
4, 6P) Connection for door call pushbutton.
5, 6S) Connection of additional door ringtone Type 860A (see variant).
Controls and adjustments
The interphone is fitted with a trimmer for adjustment of external volume,
to be adjusted only if necessary. The call volume can be adjusted by
moving the loudspeaker wirefrom connector A+ to A-; otherwise use
accessorytype 6153/682.
ID1 ID0 MONITOR
PROGRAMMING OF PHONE TYPE 62I8, 62I8/5
The operation of phone is managed by the 5 contact setting on the
phone. To activate the functions insert or remove the jumpers supplied
with phone.
Programming must be carried out before powering the installation.
Ch2
Ch1
BS
ID1
ID0
Phone identification code
When on the intallation there is more than one
Interphone
CODICE
ID1 ID0
code
phone it is necessary to identify the phone
IDENTIFICAZIONE
identification
(D)
(E)
CITOFONO
ID 0
with a different code. The identification code is
assigned by inserting the jumpers in contacts
n°1
ID 1
D and E (ID1 and ID0) as indicated in the
figure.
n°2
n°3
n°4
Intercommunicating call programming
Programming of the intercommunicating call pushbuttons (terminals 10,
11, 12) is automatic on assignment of the interphone identification code
as shown in the table below.
4
5
4
3
2
1
1 2 3 4 5
ID 0
n°1
ID 1
n°2
n°3
n°4
1 2
Jumper missing
Jumper inserted
Caller identification
code (n°)
Terminals
Call receiver identification
code (n°)
10
11
12
Lock release
Removing contact BS from the phone it is possible to open the door lock
always, with phone inserted from the call or not.. Inserting the jumper, it is
possible to release the door lock from the phone only after the call or has
been self-activated.
Association of call push-button from the entrance panel
To associate the panel pushbutton used to call the interphone, set con-
tacts A (Ch2) and B (Ch1) accordingly:: contact B for the right hand panel
push-button or 1° push-button and contact B for the left hand push-button
or 2° push-button. Inserting the jumpers the call is excluded, removing
them the call and the phone activation is enabled.
CH2
CH1
APERTURA SERRATURA SEMPRE
Jumper missing
LOCK RELEASE ALWAYS
Jumper inserted
Operation
Interphone/monitor can call other interphone or monitor types 63I8
according to the table above, but monitor types 63I8 cannot call inter-
phone types 62I8.
APERTURA SERRATURA DOPO CHIAMATA
To make an intercommunicating call, lift the handset and press the inter-
LOCK RELEASE AFTER CALL
communicating button for the interphone/monitor to be called; the maxi-
mum duration of the conversation is 60 seconds for interphone type 62I8,
while for interphones type 62I8/5 the intercommunicating conversation
duration can last up to 5 minutes. During an intercommunicating conver-
sation (or with the handset already raised) the calls from the entrance
panel do not switch the conversation automatically and the auto-start/
self-start button must be pressed (without replacing the handset) to com-
municate with the entrance panel. The conversation time between the
entrance panel and interphone can be set from 30 to 90 seconds, after
which the interphone must be called from the entrance panel within 10
seconds to proceed conversation without replacing the handset; other-
wise press the auto-start/self-start button on the interphone.
If required operate the electric lock by pressing proper push-button
. The monitor turns off after nearly 30'' (adjustable on the panel
from 30 to 90 seconds). The installation can be switched on by pressing
the push-button connected to terminal 9, thus allowing an external view
when required. When two cameras are installed, both cameras are cycli-
cally activated on pressing the push-button.
N.B.: the intercommunicating call is generated with a different ringtone
from other calls and the duration depends on activation of the call push-
button.
The selfstart/selfinsertion push-button allows the connection of interphone
or monitor to the entrance panel without being called. If there are two
entrance panels on the installation, the repeted pressure of the selfstart/
selfinsertion push-button switches the panel selection cyclically.
PT