2
Installation
2.1
Board Description (PCM100)
Voltage fuse (250Vac 3,15A)
1
2
3
4 5
6 7 8
2.1.1
Connections (PCM100)
1 - L1
2 - Ground
3 - N
4 - Pole 1
5 - Pole 2
6 - Closing
7 - Common (blu wire)
8 - Opening
9 - Pole 1 (clamp 1 BIRD)
10 - Pole 2 (clamp 2 BIRD)
11 - Common
12 - Pulse STOP (NC)
13 - Pulse A (NO)
14 - Pulse B (NO)
15 - NC
16 - Common
17 - NC
18 - 24V~ max 100mA
19 - 24V~ max 100mA
9 10 11 12 13 14 15 16 17 18 19
POWER SUPPLY
230V~ ±10% 50Hz
FLASHER 230V~
GEARED MOTOR
230V~ 700W max
BIRD ANTENNA
COMMANDS
PHOTOCELLS
(FX30D - FX40D)
Trimmer C: electr. brake / slowing down
P2: partial opening
P1: total opening
23
22
use when central unit is installed outside motor.
21
20
Opening/closing limit stop connector, to
use when central unit is installed inside moto
20 - Limit-stop connector
20 - Opening limit-stop
21 - Limit-stop common
22 - Closing limit-stop
Installation
Trimmer A: electronic clutch
Trimmer B: time of pause
LED microprocessor diagnosis
Setup Dip-Switch
LED Button P1
LED Button P2
learn remote
control code
LED closing limit stop status
Opening/closing limit stop clamps, to
LED opening limit stop status
LED photocell 2 status
LED photocell 1 status
LED STOP Status
Photocells and 24 Vac clamps
BIRD and commands clamps
Flasher and motor clamps
230Vac power supply clamps
Limit-stop connector
Use this connector only if central unit
board is installed inside of the geared-
motor.
NOTE: If it should be necessary to
invert the limit-stop wires, invert the
and
magnets at page 6.
9
10
LIMIT-STOP
Use this clamps only if central
unit board is installed outside
of the geared-motor.
21