PCM100 / PCM130 - User Manual
2.2
Board Description (PCM130)
Voltage fuse (250Vac 500mA)
1
2
Motor
2.2.1
Connections (PCM130)
1 - Motor Input
2 - Motor Output
3 - L1
4 - Ground
5 - N
6 - Pole 1
7 - Pole 2
8 - Pole 1 (clamp 1 BIRD)
9 - Pole 2 (clamp 2 BIRD)
10 - Common
11 - Pulse STOP (NC)
12 - Pulse A (NO)
13 - Pulse B (NO)
14 - NC
15 - Common
16 - NC
17 - 24V~ max 100mA
18 - 24V~ max 100mA
19 - Opening limit-stop
20 - Limit-stop common
21 - Closing limit-stop
22
3
4
5
6
7
Flasher
230Vac
GEARED MOTOR
230V~ 550W max
POWER SUPPLY
230V~ ±10% 50Hz
FLASHER 230V~
BIRD ANTENNA
COMMANDS
PHOTOCELLS
(FX30D - FX40D)
LIMIT-STOP
Use this clamps only if
central unit board is
installed outside of the
geared-motor.
8 9 10 11 12 13 14 15 16 17 18
Trimmer A: Opening time
Trimmer B: time of pause
*autoapprendimento
codice radiocomando
Setup Dip-Switch
A
P2: partial opening
P1: total opening
Opening/closing limit stop
21
clamps, to use when central
20
unit is installed outside motor.
19
LED closing limit stop status
LED opening limit stop status
LED photocell 2 status
LED photocell 1 status
LED STOP Status
Photocells and 24 Vac clamps
BIRD and commands clamps
LED Button P2
LED Button P1
learn remote