Figure 6 - 120 Vo/t AC, 20 Amp, Duplex Receptac/e
2.3.2 120VAC, 2 0 AMP, G FC/ D UPLEX R ECEPTACLE
(CARB ONLY)
This is a 120 Volt outlet protectedagainst overloadby a 20 Amp
push-to-reset circuit breaker (Figure 6A). Use each socket to
power 120 Volt AO, single phase, 60 Hz electrical loads requiring
up to a combined 2400 watts (2.4 kW) or 20 Amps of current. Use
only high quality,well-insulated, 3-wire grounded cord sets rated
for 125 Volts at 20 Amps (or greater).
Keepextensioncords as short as possibleto preventvoltage drop
and possible overheatingof wires.
Figure 6A - 120 Vo/t AC, 20 Amp, GFC/ Duplex
Receptac/e
2.3.3 120/240VAC, 3 0 AMPRECEPTACLE
Use a NEMA L14-30 plug with this receptacle (rotate to lock!
unlock). 0onnect a suitable 4-wire grounded cord set to the plug
and to the desiredtoad. The cord set should be ratedfor 250 Volts
AC at 30 Amps (or greater)(Figure7).
Use this receptacleto operate120 Volt AC, 60 Hz, single phase
loads requiring up to 3600 watts (3.6 kW) of power at 30 Amps
or 240 Volt AC, 60 Hz, single phase loads requiring up to 7200
watts (7.2 kW) of power at 30 Amps. The outlet is protected by
two 25 Amp (5.5kW) or two 30 Amp (6.5kW) push-to-resetor one
30 Amp 2-pole toggle switch or two 30 Amp push button to reset
(6.5/7.5kW) circuit breaker.
Figure 7 - 120/240 VAC, 30 Amp Receptac/e
120V/240V
30A
2.4 HOW TO USETHEGENERATOR
See the "To Start the Engine"section for how to safely start and
stop the generator and how to connect and disconnect loads. If
there are any problems operating the generator, please call the
generatorhelplineat 1-888-436-3722.
_t
ever operate in an enclosed area or indoors!
NEVER use in the home, in a vehicle,
or in
partly enclosed
areas such as garages, EVEN
IF doors and windows are open! ONLY use
outdoors and far from open windows,
doors,
vents, and in an area that will not accumulate
deadly exhaust.
_t
The engine exhaust fumes contain carbon
monoxide,
which you cannot see or smell.
This poisonous gas, if breathed
in sufficient
concentrations,
can cause unconsciousness
or
even death.
,_Adequate,
unobstructed flow of cooling and
ventilating air is critical to correct generator
operation. Do not alter the installation
or permit
even partial blockage
of ventilation
provisions,
as this can seriously affect safe operation
of the generator. The generator MUST be
operated outdoors.
_t
This exhaust system must be properly
maintained.
Do nothing that might render the
exhaust
system unsafe or in noncompliance
with any local codes and/or standards.
_t
Always use a battery operated
carbon
monoxide
alarm indoors, installed according to
the manufacturer's
instructions.