Special Functions - Watts BT-M6Z02-RF 230V Guia Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
BT-M6Z02-RF
Press > for 5 seconds, all channel leds
must blink Red. Product is waiting for
link.
Note: To exit, press > for 5 seconds.
BT-CT02-RF
Link « Circuit » device
Be careful! Link BT-M6Z02-RF to BT-CT02-RF, once ALL thermostats to BT-M6Z02-RF have been linked.

7 SPECIAL FUNCTIONS

Humidity management
This feature is available on thermostats that have Humidity sensor (BT-D02RF RH and BT-DP02RF RH).
Please refer to thermostat instruction manual to correctly set the parameters.
-
If there is a humidity default (dew point or thumidity threshold), then cooling on the zone is stopped (stops flow
in the zone).
-
If in the installation there is a BT-HCM02-RF and dehumidifier is active then if there is humidity default,
dehumidifier is active
Pump Delay (not configurable)
To avoid pump damage and noise in hydraulic circuit (Water flow in the pipe) the start-up of the pump will be
delayed for 1 minute after a heating demand from the zone thermostats. This delay should allow the actuator to
be completely opened open before the activation of the pump.
Valve exercise (not configurable)
To prevent the valves from seizing, each valve is automatically activated 2 minutes per week.
Factory settings function:
Use this function to erase all configurations, RF links and restore factory settings.
In 'Run mode', press in the same time during 5 seconds the 2 keys (◄) and (►).
Then the product has been resetted.
BT-CT02-RF
Link as a normal zone
BT-WR02-RF
Put product in RF Link mode.
10
In this configuration, BT-WR-
WR02-RF is used as hydraulic
circuit device:
Refer to the instruction manual of
BT-CT02-RF for further
explanation.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bt-m6z02-rf 24v

Tabla de contenido