Genius LYNX 07 24V Instrucciones De Uso página 21

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
Thank you for choosing our product. GENIUS is sure you will get the performances you expect to satisfy your requirements. All
our products are the result of a many years' experience in the field of the automated systems, strengthened by being part of
a world leading group in this sector.
The LYNX 07 control unit was developed and realized to control electro-mechanical barriers for vehicle access control.
Thanks to the innovative switching supply system, the control unit is able to automatically adapt to different input voltages
(230 Vac o 115 Vac) keeping unchanged the outputs value on both the motor and the accessories, without suffering any
variations.
The very simple programming of the main functions enables reduced installation times, while a series of built-in LEDs provides
for a rapid and safe diagnostics on the status of safety devices and control devices connected to the control unit.
Thanks to the encoder management, this control unit, if correctly installed and adjusted, enables you to reduce the number
of devices necessary for the realization of an installation in compliance with current safety standards.
To ensure people's safety, all war ning and instr uctions in this booklet must be carefully obser ved.
Incorrect installation or incorrect use of the product could cause serious harm to people.
Carefully read this manual before installing the product.
Store these instructions for future references.
Power supply voltage and frequency
Absorbed power
Max. power at thrust
Accessories max. load
Operating ambient temperature
Protective fuses
Function logics
Opening/Closing max. time
Pause time
Encoder sensitivity
Terminal board inputs
Rapid connector
Terminal board outputs
Board dimensions
Make sure that an adequate differential switch is installed upstream of the system as specified by current safety standards.
On the power supply mains install a thermal breaker with omnipolar switching.
Make sure that an adequate earthing system is available.
To lay cables, use adequate rigid and/or flexible tubes.
Always separate the 230/115 Vac power cables from low voltage connections, using separate sheaths to avoid possible
interference.
With reference to figure 1:
Pos.
CN1
Power supply terminal board
CN2
Motor and travel-limit terminal board
CN3
Light outputs terminal board
CN4
Inputs terminal board
CN5
Battery terminal board
JP1
Not used
JP2
Radio module rapid coupling
JP3
Encoder connection Molex
F1
Power supply 230/115Vac circuit fuse
F5
Motor power supply circuit fuse
1. GENERAL CHARACTERISTICS
2. TECHNICAL SPECIFICATIONS
230 Vac 50 Hz / 115 Vac 60 Hz
5 W
280 W
500 mA
-20°C +55°C
2 fuses, replaceable + 4 fuses, self-resetting
Automatic (A) / Step-by-step automatic (AP) / Manual (E) / Step-by-step
manual (EP) / Condo (D)
60 seconds
Adjustable on 7 levels of 5 seconds up to 4 minutes
Adjustable on four levels
Mains power supply (230/115 Vac) / FCA and FCC travel limits/ Photocells /
Stop/ Open-Close / Open / Close / Safety dev. test / Battery
3-pin molex coupling for encoder / 3-pin input for receiving module
Motor power supply 24Vdc / Flashing lamp 24Vdc / Indicator light 24Vdc max.
5W / Rod lights 24Vdc / Power supply to accessories / Battery charger
168mm x 146mm
3. PREPARATIONS
4. BOARD LAYOUT
Description
LYNX 07 24V
Pos.
OP
OPEN input radio programming push-button
O/C
OPEN/CLOSE input radio programming push-button
FCA
FCA input signalling LED
FCC
FCC input signalling LED
FSW
SAFETY DEVICES input signalling LED
STOP
STOP input signalling LED
OP/CL
OPEN/CLOSE input signalling LED
OPEN
OPEN input signalling LED
CLOSE
CLOSE input signalling LED
DL6
OPEN/CLOSE radio input signalling LED
Page 7