Genius LYNX 07 24V Instrucciones De Uso página 28

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
Page 24
LYNX 07 24V
Guide for the installer
Display
Parameter
Value
Behaviour in the event of a power cut: This parameter is used to select the behaviour of the automated system when mains
Without battery kit: If mains power fails, the automated system remains in the position it is in that
0
Without battery kit: If mains power fails, the automated system remains in the position it is in that
1
With battery kit: If mains power fails, the automated system continues its normal operation. At the end
0
With battery kit: If mains power fails, the control unit automatically commands an opening movement
1
Immediate closure: If this function is activated, when the automated system is open in pause and the photocells detect a
transit, the photocells command an automatic re-closure of the automated system without waiting for the
pause time to elapse
0
Immediate closure disabled
o
1
Immediate closure activated
Immediate closure/Timer: This function is used to select the immediate re-closure of the automated system or stop with the
OPEN/CLOSE input
Immediate closure: When the automated system is open in pause, an impulse of the OPEN/CLOSE
0
P
Timer function: When the automated system is open in pause, an impulse of the OPEN/CLOSE input
1
Fototest: If this function is activated, the control unit performs a check of the correct operation of the connected safety devices
before each closing movement
0
Fototest function disabled
S
1
Fototest function activated
Safety devices: This function is used to select the type of activation of the connected safety devices: active only during the
closing movement of the automated system or active during opening, too.
0
Safety devices active only during the closing movement of the automated system
y
1
Safety devices active during the closing and opening phase of the automated system
power is cut.
moment. When the mains power is present again, the control unit automatically
commands, after two seconds, a beam re-closure and prepares for normal ope-
ration. The first opening movement performed by the automated system occurs
at decelerated speed.
moment. When mains power is present again, send an OPEN or OPEN/CLOSE
pulse to resume normal operation of the automated system. When mains power
is present again, the first two (closing and opening) movements performed by
the automated system occur at decelerated speed. The automated system
resumes normal operation only after having carried out an opening movement
at decelerated speed.
of each opening movement, the flashing lamp (external flashing lamp or strip on the
upright sides) flashes twice in succession with a 3-second interval, up to a maximum
of 30 seconds, indicating that the system is only supplied by batteries. When the mains
power is present again, the system resumes its normal operation When batteries are
flat, the automated system behaves as buffer batteries have not been connected.
of the automated system and stops the rod in opening position disabling all commands.
When the mains power is present again, if automatic re-closure was selected, the
control unit automatically commands the beam re-closure and sets for normal
operation. If the automatic re-closure was not selected, when the mains power is
present again, the automated system waits for a CLOSE or OPEN/CLOSE command
to resume normal operation. When batteries are flat, the automated system behaves
as buffer batteries have not been connected.
.
a
input
.
b
command causes the automated system to start the closing phase without waiting
for the pause time to elapse.
causes the control unit to resume the pause time count. If the OPEN/CLOSE command
is held down, the pause time count stops. When the command is released, the control
unit resumes the pause time count and then closes.
.
c
Description

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido