Technical Specifications; Electric Connections - Genius JA383 Instrucciones Para El Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

1.
WARNINGS
Important: Before attempting any work on the control board
(connections, maintenance), always turn off power.
- Install, upstream of the system, a differential thermal breaker with
adequate tripping threshold.
- Connect the earth cable to the appropriate terminal on the J7
connector of the equipment (see fig.2).
- Always separate power cables from control and safety cables
(push-button, receiver, photocells, etc.). To avoid any electric
noise, use separate sheaths or a shielded cable (with earthed
shield).
2.

TECHNICAL SPECIFICATIONS

Power supply
Absorbed power
Motor max. load
Accessories max. load
Operating ambient temperature
Protection fuses
Function logics
Semi-automatic / Safety devices / Semi-automatic B /
Work time
Pause time
Thrust force
Terminal board inputs
Open / Partial opening / Safety devices at opng. /
Safety devices at clsng. / Stop / Edge / Power supply + Earth
On-connector inputs
Opening and closing limit-switches / Encoder
Terminal board outputs Flashing lamp - Motor - 24 Vdc accessories power
supply - 24 Vdc indicator-light / Timed output. - Fail safe
Rapid connector 5-pin card connection for Minidec, Decoder or RP receivers
Programming
3 keys (+, -, F) and display, "basic" or "advanced" mode
Basic mode programmable functions
Advanced mode programmable functions
Fail safe - Pre-flashing - Indicator-light/Timed output -
Encoder - Decelerations - Partial opening time -
Work time - Assistance request - Cycle counter
4.

ELECTRIC CONNECTIONS

J5
LIMITS
ENCODER
ENCODER
(optional)
LIMIT-SWITCH
CONTROL BOARD JA383
115 V~ - 50 Hz
10 W
1200 W
0,5 A
-20 °C +55 °C
2 (see fig. 1)
Automatic / "Stepped" automatic /
Dead-man C / "Stepped" semi-automatic
Programmable (from 0 to 4 min.)
Programmable (from 0 to 4 min.)
Adjustable over 50 levels
Function logic - Pause time - Thrust
Force - Gate direction
Torque at initial thrust - Braking -
Opening and closing safety devices logic -
J3
1
2
3
4
5
6
ACCESSORIES
PARTIALLY OPEN
TOTALLY OPEN
3.
LAYOUT AND COMPONENTS
RADIO
J2
FCA
J2
FCC
ENCODER
J5
J3
J3
J5
LIMITS
ENCODER
DL
Led
J1
J2
J3
J5
J6
J7
F1
F2
F
+
-
-
J1
7
8
9 10 11 12
24 Vdc
3 W
For connection of the
photocells and safety
devices, see paragraph
4.1.
NB.: The capacitor is supplied with the operator.
9
DL
-
+
F
+
F
FSW
OPEN
STOP
OP
B
Led
OPEN
FSW
EDGE
A
CL
SAFE
- -
1
2
3
4
5
6
7
8
9 10 11 12
J1
ACCESSORIES
SIGNALLING AND PROGRAMMING DISPLAY
INPUTS STATUS CONTROL LED
LOW VOLTAGE TERMINAL BOARD
CONNECTOR FOR DECODER/MINIDEC/RP RECEIVER
ENCODER CONNECTOR
LIMIT -SWITCH CONNECTOR
MOTORS AND FLASHING LAMP CONNECTION TERMINAL BOARD
115 VAC POWER SUPPLY TERMINAL BOARD
MOTORS AND TRANSFORMER PRIMARY WINDING FUSE (F 10A)
LOW VOLTAGE AND ACCESSORIES FUSE (T 800mA)
"F" PROGRAMMING PUSH-BUTTON
"–" PROGRAMMING PUSH-BUTTON
"+" PROGRAMMING PUSH-BUTTON
J6
13 14 15 16 17
PE N
MOTOR
LAMP
C
M
115 Vac
max. 60W
STOP
ENGLISH
F2
F2
F1
F1
J7
J1
J6
13 14 15 16 17
PE N
L
J6
MAIN
J7
MOTOR
LAMP
Fig. 1
J7
L
MAIN
115 Vac
50 Hz
Fig. 2

Publicidad

Tabla de contenido
loading

Tabla de contenido