Sensor configuration
Connector 1 sensor types
Note: the underlined value/command is the default value/command. The units of measure depend on
parameter SYSTEM CONFIG > Units
Frequency pin 4
Resistive pin 8
Resistive pin 9
Voltage pin 10
Current pin 11
Current pin 12
Note*: the displayed ID is increased by 1 from the NMEA ID (i.e. Engine 1=NMEA 0 ID, Engine 2= NMEA 1
ID, etc.).
70
7" TFT display | Operating instruction v. 1.0 | © 2018 Continental Automotive Switzerland AG
Setting
Description
Impulses per engine revolution. If
enabled, engine revolutions are read
by the analog frequency sensor.
Input 8 sensor
Input 9 sensor
Input 10 sensor
Input 11 sensor
Input 12 sensor
Possible values/commands
Off / On
Show value as: Engine 1 - 4. Connected engine ID*
Pulse per revolution: 0.0 – 655.34 (1.0). Offset factor to
calculate the engine revolution number based on the frequency
signal value.
Input:
Off: no connected analog sensor
l
Trim
l
Fresh water: fresh water level
l
Rudder: rudder angle
l
Fuel: fuel level
l
Eng cool temp 40 - 120 °C: coolant temperature
l
Eng oil temp 50 - 150 °C: engine oil temperature
l
Engine oil pres 0 - 5 bar / Engine oil pres 0 - 10 bar:
l
engine oil pressure
Boost pressure 0 - 2 bar: boost pressure
l
Show value as:
Fuel: Tank 1 - 4. Connected tank ID
l
for engine sensors: Engine 1 - 4. Connected engine ID*
l
Calibration:
for Fuel: one or three point calibration (see "Configure and
l
calibrate the fuel level sensor" on page 68)
for Trim, Fresh water and Rudder: three point calibration
l
(see "Configure and calibrate the other sensors" on the
previous page)
Input:
Off: no connected analog sensor
l
Ext illum: brightness control (day-night) from external
l
control
Engine oil pres 0 - 10 bar/ Engine oil pres 0 - 16 bar /
l
Engine oil press 0 - 30 bar: engine oil pressure
Show value as: Engine 1 - 4. Connected engine ID*
Input:
Off: no connected analog sensor
l
Fresh water: fresh water level
l
Waste water: waste water level
l
Show value as: Tank 1 - 4. Connected tank ID
Calibration: three point calibration (see "Configure and
calibrate the other sensors" on the previous page)