Descargar Imprimir esta página

How It Works - Eaton Metalux SVP Serie Manual De Instalación Y Empleo

Publicidad

Idiomas disponibles

Idiomas disponibles

Eaton Integrated Sensor System - SVPD1, SVPD2, SVPD3 series
Capture the benefits of traditional lighting controls, without complicated coverage planning or special wiring using a sensor in
every fixture. Ideal for new construction or retrofit fixtures. With the SVPD series, integrated sensors have automatic occupancy
detection and daylight dimming out of the box, immediately saving energy. The lighting system will turn on automatically, dim to
a preset level, and begin to raise/lower to a default light level. The fixture will also turn off when no one is around.
The integral daylight sensor* reduces the need for special daylight zone planning. Each luminaire will automatically adjust the
light level based on reflected light beneath the sensor.
Occupied daylight light levels and unoccupied light levels can be adjusted using the integrated sensor programming remote
(Catalog Number: ISHH-01). The integrated sensor personal remote (Catalog Number: ISHH-02) provides code compliant
(ASHRAE, IECC, T24) manual raise, lower, ON, OFF control.

How it works:

• As the user enters the space controlled by the integral sensor, the lighting turns ON to the default daylight level.
• Lighting will remain at that the daylight level until the space is unoccupied. This will start the occupancy timeout period
(default 20 minutes).
• If the space remains unoccupied for half of the timeout period, the lighting will automatically reduce to the Energy Saver
light level. This adjustable light level is typically half of the occupied daylight level.
• At the end of the timeout period the lighting will go to the unoccupied light level. This adjustable light level uses the OFF
default setting.
• Use the ISHH-01 Programming remote to customize the settings and time values. Refer to the Integrated Sensor
programming guide for more information. Use the ISHH-02 Personal Control remote to temporarily turn the lighting on or
off, or change the light level, all without interrupting the programmed settings.
*Daylight sensing not available on some models.
100
(DO)
Daylight Level
0
Unoccupied
Occupied
R em o t e C o n t r ol
ISHH-01
Programming/Control
Remote
(1)
Notes:
(1)
Compatible with SVPD series only.
SVP series integrated sensor system information continued on next page
Installation Instruction Supplement - Metalux Luminaire with Integrated Sensor
Energy Savings
Opportunities
(ES)
Energy Saver
Light Level
(DU)
Timeout Value
Unoccupied Level
Unoccupied
Programming Remote Functionality
1.
An optional programming remote is available to
change the integrated sensor default settings.
2.
Only one remote is needed to program
multiple luminaires with integrated sensors.
3.
Refer to the Integrated Sensor Remote
Programming Guide for detailed
information on the use and
programming of the integrated
sensor and programming remote.
ISHH-02
Personal Control
Remote
(1)
Installation Instruction Supplement –
ADF142495
(DO)
Daylight Level
Occupied
www.eaton.com
For default settings by luminaire series,
consult the integrated sensor (SVPD1,
SVPD2, SVPD3). Specification sheet
supplement located at www.eaton.com/
lighting
(1)
3

Publicidad

loading