VPEV-1/8-M12
10
Technical specifications
Type
Part no.
Design
Medium
Fitting position
Connection
Setting range
– vacuum
– comp. air switching point
Switching point
Hysteresis
Permitted temperature range
Max. Operating voltage
Switching current
Rated measuring current
– Ohmic load
– Inductive load
Min. loading current
Max. contact loading
– ohmic load
– inductiveve load
Festo 0007NH– English
VPEV-1/8-M12
192 489
Mechanical vacuum switch/pneumatic- electric
signal converter
Vacuum/filterd (40 m m), lubricated or nonlubri-
cated compressed air
as desired
G 1/8 (pneumatic); M12 (electrical)
switching point
-0.2 ... -1 bar
hysteresis
0.16 ... 0,55 bar
0.16 ... 1.6 bar
hysteresis
0,20 ... 0,70 bar
-0.5 bar
0.3 bar
- 20 °C ... + 80 °C (dew point must not be reached
at temperatures < 1 °C; use dried air)
DC/AC 48 V (Rated measuring voltage: DC 24 V)
5 A (ohmic load)
4 A
3 A
1 mA (DC/AC 24 V)
10 mA (DC/AC 10 V)
100 mA (DC/AC 5 V)
DC 30 V
DC 30 V
±
0.04 bar (as supplied from factory)
±
0.06 bar (as supplied from factory)
5 A
3 A
21