thickness of 19mm (3/4"). Do NOT screw directly onto the hull, it must be mounted to
a bulkhead or on an additional board.

7. PARTS LIST

1 x Orca Pump

8. OPTIONAL EXTRAS

BE9003 / BE9006 - Electric Field Sensor Switch (Available separately)
9. INSTALLATION
WARNING: Please note that incorrect installation may invalidate the warranty.
Preparation - Always disconnect power sources before installing.
9.1 Location
Position pump in the lowest accessible
part of the bilge. On sailboats, location
should be centred over keel (Fig 1).
Do not mount the pump directly onto
the hull. The base strainer must be
mounted to a bulkhead or an additional
board at least 19mm (3/4") thick.

9.2 Mounting Instructions

Before drilling, ensure that the mounted pump will be correctly positioned with the pump nozzle
pointing towards thru-hull connector.
To remove pump body, place hand over body, depress locking tabs and lift body from strainer base.
Note: Motor will be removed with body (see figure 2 and 3).
For Orca 500, 950, 1300 and 2000
Use base as template to mark 3 mounting holes for Orca in
mounting pad.
Remove base. Drill three 1/8" (3mm) pilot holes for Orca at
marked locations.
Replace base. Attach with #8 stainless steel fasteners
(supplied).
Re-attach pump body to base. Insert body into strainer
base, until base tabs snap into holes in body (see figures 2
and 3).
For Orca 3000
Use base as template to mark 4 mounting holes for Orca
3000 in mounting pad.
Remove base. Drill four 1/8" (3mm) pilot holes for Orca
3000 at marked locations.
Replace base. Attach with #8 stainless steel fasteners
(supplied).
Re-attach pump body to base. Insert body into strainer
base, until base tabs snap into holes in body (see figure 3).
9.3 Plumbing
IMPORTANT: To prevent airlock, hose must rise continually upward to the thru-hull connector with
no dips or sharp bends. Hose support clips should be used at regular intervals where necessary.
Orientate the pump outlet for a direct path to the hull connector ensuring an
unobstructed hose path.
Secure all connections with hose clamps.
If no thru-hull connector exists, install at 12" (305mm) minimum height above water
line. Apply marine sealant around thru-hull flanges on interior and exterior of hull.
1 x Screw Kit
Figure 1 -
Mounting Location
Hose must rise upwards
with NO DIPS
Suitable Mounting Pad
Press
both
locking
tabs to
release
cover
Press both
locking tabs
to release
cover
Skin Fittings
Outlet 12"
(305mm)
minimum
above
water line
Figure 2 - Release Cover