Sediment Trap Assembly - L.B.White Guardian AW060 Manual De Instrucciones

Ocultar thumbs Ver también para Guardian AW060:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Guardian LP or Natural Gas Heater
12

Sediment Trap Assembly

Assemble the tee, nipples and cap together and
tighten securely. See Fig. 4. The sediment trap
assembly must always be mounted in a vertical
position. Make sure pipe thread compound that is
resistant to both L.P. gas and natural gas is used in
making all connections. Check all connections for
gas leaks using approved gas leak detectors.
FIG. 4
NIPPLE
TO GAS CONTROL
VALVE INLET
Manual Shut-off Valve,
Hose & Regular
Assembly
(Must be ordered separately)
1. Always use approved pipe thread compound
suitable for use with L.P. gas or natural gas on the
threaded connections.
2. Assemble the components together according to
Fig. 5. This view is to show general assembly of
the components only. The regulator must always
be mounted so its vent, regardless of location on
the regulator, is always pointed downward.
Note: Regulators located in doors should be vented
back to outdoors. Refer to NFPA54, National
Fuel Gas Code Handbook, CAN-B1491, CAN-
B149,2, & local codes as appropriate.
3. Tighten all connections securely.
4. Check all connections for gas leaks
using approved gas leak detectors.
Owner's Manual • Guardian
HOSE ADAPTER
TEE
NIPPLE
CAP
FIG. 5
REGULATOR VENT
TO CONTROL
VALVE INLET
REGULATOR
NIPPLE
VALVE, MANUAL
SHUT-OFF
GAS HOSE
ADAPTER
SEDIMENT TRAP

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Guardian aw100Guardian aw250Guardian aw325

Tabla de contenido