L.B.White Guardian AW060 Manual De Instrucciones página 4

Ocultar thumbs Ver también para Guardian AW060:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Guardian LP or Natural Gas Heater
4
Specifications
Maximum Input (btu/h)
Minimum input (btu/h)
Ventilation Air Required To Support
combustion (cfm)
Gas Supply Pressure
Acceptable at the
Inlet of the Heater for
the (Max.) purpose of
Input Adjustment (in.
W.C.)
Burner Manifold
Pressure (in. W.C.)
Fuel Consumption
Per Hour
Motor Characteristics
Electrical Supply
(Volts/Hz/Phase)
Amp Draw
(Includes Ignitor)
Dimensions (In.) (L x W x H)
Minimum Safe
Distances from
Heater to
Nearest Combustible
Materials
Owner's Manual • Guardian
AW060
60,000
30,000
240
LP Gas
Max.
Min.
Nat. Gas
Max.
Min.
LP Gas
Nat. Gas
LP Gas
Max.
2.78
(lbs)
Min.
1.39
Nat. Gas
Max.
(cu. ft.)
Min.
H.P.
1/15
RPM
1700
Starting
7.0
Continous
1.1
21¼x14¼x18
Top
Sides
Back
Blower Outlet
Gas Supply
AW100
100,000
50,000
400
13.5
11.0
13.5
7.0
10.0
4.0
4.63
2.32
60
100
30
50
Ball Bearing
1/8
1100
120/60/1
7.5
1.4
29½x14¼x18
1 ft. (0.3 m)
1 ft. (0.3 m)
1 ft. (0.3 m)
6 ft. (1.83 m)
LP Gas - 6 ft. (1.83 m) Natural Gas: N/A
AW250
AW325
250,000
325,000
160,000
200,000
1050
1700
8.0
3.5
11.58
15.08
7.41
9.28
250
325
160
200
1/3
1/2
1075
1100
240/60/1
11.8
10.5
4.5
3.5
30¾x18¼x28¼
36x22x30

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Guardian aw100Guardian aw250Guardian aw325

Tabla de contenido