Descargar Imprimir esta página

Hayward ZKD Serie Manual De Instalación página 7

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Display during Operation
Operating mode
Weekly timer
Alarms and statuses
Lev = Level alarm
Flw = Flow alarm
Mem = Memory alarm
Paragraph 3 – Timed Dosage (Frequency signal input "TRIGGER" activated)
Programming
PROG
Configuration
Configuration
Pump functions
-
+
Pump functions
Time
Time
-
Quantity
100ml
Time
g.hh.mm
-
Delay
0.01.50
Time
g.hh.mm
-
interv.
0.01.50
Trigger Mode
-
N. Open
Pause Input Mode
Trigger Mode
-
Relay
-
Off
Hayward Flow Control
FLOW
sensor
Day of the week
status
Displays the quantity during
dosages
Weekly
F
Mon
F
F
Lev
Stop
12.01
Time
Pump status
Empty = pump in start
Stop = pump stationary
Paus = pump in pause
-
+
-
+
-
+
Trigger Mode
-
N. Open
Trigger Mode
-
N. Closed
Trigger Mode
Disable
-
+
www.haywardflowcontrol.com
Display during Setting (MODE key)
Operating mode
Displays in sequence:
programme number, activation
time, quantity, dosage time,
relay status.
P01:START
Displays hours
14.40
and minutes
Time
• Displays hours and minutes
After receipt of the TRIGGER signal set, the pump doses a
quantity that can be programmed in ml. It is possible to set a
delay time before the dosing (Delay) and the interval between
subsequent dosings (Interv.) as illustrated in the diagram:
Trigger
Delay
By setting for example an Interval. time = 0, a system is
obtained in which the programmed quantity is dosed after each
TRIGGER signal (with any delay that has been set):
Trigger
Delay
It is possible to start the dosing by pressing the + key, which, in
practice, simulates the Trigger signal.
The Trigger signal can be set to N. Open (it is activated when
the input passes from the open to the closed mode) or to N.
Closed (it is activated when the input passes from the closed to
the open mode).
The Trigger signal is locked during dosing (its receipt is neither
stored nor managed).
The Pause (Remote input) input cannot be programmed and
its activation stops the dosing, while its further deactivation
makes the system wait again for the Trigger signal for a new
dosing.
The dosage frequency can be modified while the pump is
operating, by pressing the
increase the frequency, or the
The values of the relay connected to dosage can be modified
using the
keys and confirmed by pressing the
Day of the
week
Mon
12.01
Operation
Quantity
Interv.
Release
Ritardo
keys at the same time to
keys to decrease it.
1-888-INDL (1-888-429-4635)
ZKDIOM
Pg. 5 of 10

Publicidad

loading