3. Declaration of Conformity

According to Machinary Directive (2006 / 42 / EC) attachment II 1.A
Herewith we declare that the machine described below is in its conception and design and in
the shape delivered by us in accordance with the fundamental requirement for safety and health
as prescribed in the applicable EC-guidelines. In the case of any change or modification of the
machine not authorised by us this declaration becomes invalid.
Denomination of the machine:
Drufomat scan
:
D3400 / D3400A / D34001 / D34001A
Type of machine:
Pressure thermoforming unit
The following additional ECdi-
rectives were applied:
2006 / 35 / EC
Low Voltage Directive
2014 / 35 / EU
EMC Directive
The protection objectives of EC Directive 2006 / 42 / EC are complied with.
Applied harmonised standards:
2006 / 42 / EC
According to Machinery Directive
EN ISO 12100:2010 +
Safety of machinery – General principles for design – Risk assesment and
risk reduction (ISO 12100:2010); German version EN ISO 12100:2010
Corrigendum to DIN EN
+ Corrigendum to DIN EN ISO 12100:2011-03.
ISO 12100:2011-03
EN ISO 13732-1:2008 Ergonomics of the thermal enviroment – Methods for the assessment of
human responses to contact with surfaces – Part 1: Hot surfaces (ISO
13732-1:2006); German version EN ISO 13732-1:2008-12.
EN 60204-1:2006 / A1:
Safety of machinery – Electrical equipment of machines – Part 1: General
2009 + Corrigendum to
requirements (IEC 60204-1:2005 / A1 2008); German version EN 60204-
60204-1:2006
1:2006 / A1:2009 + Corrigendum to EN 60204-1:2006; German version
CENELEC-Cor.: 2010 to EN 60204-1:2006.
2014 / 35 / EU
Low Voltage Directive
EN 61010-1:2010
Safety requirements for electrical equipment for measurement, control
and laboratory use – Part 1: General requirements (IEC 61010-1:2010
+ Cor.: 2011); German version EN 61010-1:2010.
2014 / 30 / EU
EMC Directive
EN 61000-3-2:2014
Electromagnetic compatibility (EMC) – Part 3-2: Limits – Limits for har-
monic current emissions (equipment input current <= 16 A per phase)
(IEC 61000-3-2:2014); German version EN 61000-3-2:2014.
EN 61000-3-3:2013
Electromagnetic compatibility (EMC) – Part 3-3: Limits – Limitation of voItage
changes, voItage fluctuations and flicker in public Iow-voltage supply systems,
for equipment with rated current <= 16 A per phase and not subject to condi-
tional connection (IEC 61000-3-3:2013; German version EN 61000-3-3:2013.
EN 61326-1:2013
Electrical equipment for measurement, control and laboratory use – EMC
requirements; Part 1: General requirements (IEC 61326-1:2012); German
version EN 61326-1:2013 Emission according to living area, business
and industrial undertakings as well as small enterprises interference
stability according to industrial area.
Dreve Dentamid GmbH · Max-Planck-Straße 31 · 59423 Unna / Germany
Tel.: +49 2303 8807-40 · dentamid@dreve.de · www.dentamid.dreve.de
28

4. Safety advice

Attention! Read the following notes before connecting and putting the unit into ser-
vice. The operating service and the function of the unit can only be guaranteed for, if
the general safety and accident prevention instructions of the legislation as well as the
safety instructions of the working instructions are observed.
1. This unit must only be used accord-
and understood the manual. Only in
ing to the present working instructions.
that case the operators may operate
We cannot be held liable for damages
the unit.
which have been caused by improper
treatment resp. faulty manners of oper-
8. The unit has to be examined before
ation.
operation in view of proper condition
and operating safety. If the unit is not
2. Put the unit on a stable and even
in proper condition, it must not be used
basis which is suitable for the opera-
and has to be marked accordingly.
tion weight of approx. 15 kg of the unit.
9. The pressure of the compressed air
3. In order to avoid the intrusion of
line must not exceed 10 bars.
water into the unit (e. g. splash water)
10. Do not intrude any objects into
the unit is to be placed into a dry sur-
rounding.
the unit.
4. Do not store any flammable sub-
11. Do not lock-up the operation ele-
stances in the close surrounding of
ments of the unit.
the unit.
12. Do not block the downwards-mov-
5. The indicated voltage on the type
ing piston.
plate has to meet the voltage of the
13. Do not touch the downwards-mov-
power source.
ing piston.
6. The unit must only be connected
with a socket with protective conduc-
14. The swivelling housing of the radia-
tor. Never touch the plug with wet
tor reaches high temperatures and must
hands.
therefore not be touched – not even for
7. Authorised operators: The operating
short moments.
company of the machine has to hold
the working instructions at the oper-
15. If the unit is not used, please dis-
ators' disposal and has to make sure
connect the mains.
that authorised operators have read
29