Drufosmart scan
9.2 Creation and storage of manual time programmes
Up to three individual time programmes
may be created and stored for thermo-
forming foils that are not equipped with
a corresponding barcode.
Turn on the unit – the initial display
will be visible. When pushing the menu
key (j) one time the display will show
– – – – – at position b.
As described in point 9.1, push menu
key (j) and select the desired heating
time by the menu keys +/- (e/i). Follow-
ing push menu key (j) again and enter
cooling time.
38
For single use confirm the two entered
values by pushing OK (f). Then go on
as described in point 8.2.
If the created time programme is to
be stored for repeated use, 3 memory
capacities (F1–F3) are available.
Do not confirm the created time pro-
gramme by pushing OK, but press menu
key (j) again. The display will show F1
in position b, the entered times will be
taken over. The memory capacities F2
and F3 can be selected by pushing the
menu key (j) 2 resp. 3 times. Store the
times in the desired memory capacity
by pushing the OK key (f).
Then go on as described in point 8.2.
9.3 Calling of individual time programmes
Turn on the unit – the initial display
will be visible. By pushing the menu
key (j) several times you may select one
after another:
a) enter modus
b) F1
c) F2
Then go on as described in point 8.2.
d) F3
By pressing the menu keys (d/j) you may
navigate arbitrarily between the a. m.
programme points. Confirm the selected
programme point with the OK key (f).
9.4 Plasticizing of blanks with unknown heating times
tacts and the necessary flexibility
Create an individual time programme
with high heating and cooling times
will be attained at last!
(see point 9.2). Start the programme
(see point 8.2). You may test the
After the blank has attained the neces-
plasticization degree of the blank by
sary flexibility initiate the thermoform-
means of an edgeless metal instrument
ing process (see point 8.4). The remain-
(e. g. wax knife).
ing heating time will be erased from
the display (a) and the adjusted cooling
Info
time will be counted down (c).
The complete deformability of the
blank can only be tested at the
The cooling time can be terminated at
edges, as that is where warmth
any time by pulling the heating han-
will leak through the metal con-
dle (5).
9.5 Abort/termination of programme
During an active time programme the
Drufosmart scan by pulling the heat-
key pad is deactivated. It is possible
ing handle (5) as far as it will go (for
to abort/terminate all actions of the
approx. 3 seconds).
39