E N
Problem
The machine won't switch on.
The lights flash quickly.
The capsule load lever won't
return to the closed position.
The pump is very noisy.
The machine doesn't dispense
any coffee.
The coffee comes out too quickly,
there is no crema in the espresso.
No foam is formed in the milk or
cappuccino.
No steam is dispensed
The machine does not reach the
correct temperature (LAVAZZA-
TIME sign off ).
For problems not covered by the above table, or in the event that the suggested solutions do not resolve the
· Voltage: 220-240 V, 50-60 Hz
· Total power: 1000 W
· Water tank capacity: 2.7 l
· Weight: 7.2 kg
· Materials used for machine body: thermoplastic
· Used capsule tray capacity: approx. 25 single-serving capsules
20
TROUBLESHOOTING
Possible causes
»
Machine not connected to
power source.
»
There is a fault.
»
The drop collection/used cap-
sule tray is full.
»
Capsule inserted incorrectly.
»
Not enough water in water tank.
»
Filter inserted incorrectly.
»
No capsule inserted.
»
Required temperature not yet
reached.
»
Capsule load lever up.
»
Not enough water in water tank.
»
Filter inserted incorrectly.
»
The inserted capsule has already
been used.
»
Milk not suitable.
»
Milk not cold enough.
»
Steam dispenser tube blocked.
»
Steam arm/hot water tube
blocked.
»
Not enough water in water tank.
»
Filter inserted incorrectly
»
Starting temperature too low.
problem, contact a Lavazza service centre
TECHNICAL SPECIFICATIONS
For technical specifications please refer to the data plate found on the machine.
Solution
»
Check it is plugged in correctly.
»
Contact customer services or the service
centre.
»
Empty the drop collection/used capsule tray.
»
Lift the capsule load lever and correctly insert
the capsule.
»
Fill with fresh drinkable water.
»
Check that the Brita® is inserted correctly (see
instructions supplied with filter).
»
Insert capsule.
»
Wait until the correct temperature has been
reached.
»
Lower the capsule load lever.
»
Fill with fresh drinkable water.
»
Check that the Brita® is inserted correctly (see
instructions supplied with filter).
»
Insert new capsule.
»
Use fresh, semi-skimmed milk.
»
Use refrigerated milk.
»
Clean the steam tube with a needle and
clean the steam arm.
»
Clean the steam arm (see maintenance and
cleaning); if the problem persists clean the dis-
penser hole with a thin needle, making sure it
is free of blockages, then turn on the machine
and dispense a small quantity of steam.
»
Fill with fresh drinkable water.
»
Check that the Brita® is inserted correctly (see
instructions supplied with filter).
»
Turn off the machine and turn it on again.
· Clock digit dimensions 50 mm x 15 mm
· Dimensions: Height
Width
Depth
2006/42 CE – 2004/108 CE – 2006 /95 CE
310 mm
300 mm
323 mm