Changing Gas - Proline PGC5050W-F Manual De Instalacion Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3. INSTALLATION

3.6 Changing gas

!
Warning : The following procedures must be undertaken by authorised service personnel.
Your cooker has been designed to use either liquefied petroleum gas (propane or butane), or
natural gas. The gas burners can be adapted to these different types of gas, by replacing the
corresponding injectors and adjusting the minimum flame length of each burner. The steps
below must be strictly carried out:
Changing Injectors:
Cooktop burners:
Shut off main gas.
Remove the burner cap and the upper burner (Figure 8).
Unscrew the injectors. For this, use a 7mm spanner (Figure 9).
Install the new injectors in accordance with the type of gas used, as shown on the technical data
table. Be careful to tighten straight the new injectors, because if you mount them sideways, you will
damage the thread of the rack and the rack will need to be changed (and it will not be in guarantee
extent).
Oven Injectors :
The oven burners are fitted by a single screw that is placed on the tip of the burner.
For the oven burner (below), open the oven door, remove the screws holding the lower sheet.
Open the compartment beneath the oven (pull-down door) to access the front screw located on
the burner (Figure 11). If the cooker has a sub-oven front , you must first dismantle the oven
door to gain access to the screws holding the sheet.
Figure 8
12
Spanner
Injector
Figure 9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pgc5060sl-fPgc5060w-f

Tabla de contenido