Product Specifications - Speedrite 15 J Unigizer Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12
Identifying faults using the LCD display
and the indicator lights
If...
This means that...
The energizer is not
The battery connections may be faulty. Check all
pulsing and the first red
battery connections. Check the battery voltage
Indicator light is
immediately using the battery test setting. See
Testing the battery voltage
flashing...
The first red Indicator
The energizer has a fault. If the display persists
light is flashing and other
and does not return to normal, contact your
indicator lights are on...
service agent for advice.
The energizer is pulsing
The battery voltage may be low and the energizer
slowly and has a reduced
has reverted to Slow Speed and Low Output
output voltage...
Power in order to preserve the remaining power
and energy in the battery.
The warning light is
The energizer has detected a sudden increase in
flashing and the warning
the load on the fence.
buzzer is sounding...
Switch the energizer off, locate and remedy fault
then turn the energizer on again.
For example, this may occur:
The output voltage digits
The fence voltage is below 1000 V. There is a
(large digits on the LCD
serious fault on the fence line. See "How do I
display) flash 1.0 kV...
locate faults?" in
questions/Troubleshooting
The first red Indicator
The earth monitor voltage is too high. Use the
light is illuminated
earth monitoring feature to monitor the earth.
permanently...
See

Product specifications

Power supply
Power consumption using a power adaptor
Current consumption using a 12 V rechargeable battery
Battery Test
Slow Speed-Day/Fast Speed-Night
Fast Speed-Day/Slow Speed-Night
Half Output Power
Full Output Power
Maximum output voltage
Maximum output energy
Maximum stored energy
Values are typical and normal production tolerances of ±5% should be allowed for.
on page 5.
if a cutout switch is closed, connecting a
heavily loaded section of the fence to the
energizer
if a branch falls on the fence
if the fence or cable connecting energizer to
it experiences a sudden short to ground
if something becomes entangled in the
fence.
Frequently asked
on page 10.
Earth monitoring
on page 5.
If...
The battery symbol on
the LCD is flashing...
The right arrow on the
LCD is flashing...
The energizer is not
pulsing and the last
green Indicator light is
flashing...
Servicing
This energizer uses Double Insulation, where two systems of insulation are
provided instead of grounding. No equipment grounding means is
provided in the supply cord of a double-insulated energizer, nor should a
means for equipment grounding be added to the energizer. Servicing a
double-insulated energizer requires extreme care and knowledge of the
system and should only be done by qualified service personnel.
Replacement parts for a double-insulated energizer must be identical to
the parts they replace. A double-insulated energizer is marked with the
words DOUBLE INSULATION or DOUBLE INSULATED and/or the symbol
below.
12 V battery,
or approved power adaptor 100-240 V
18 W
750 mA
750 mA (day)
1250 mA (night) or
1000 mA (24 hour average)
1250 mA (day)
750 mA (night) or
1000 mA (24 hour average)
630 mA
1250 mA
9.9 kV
14.6 J at 50 Ω
18.3 J
This means that...
The battery voltage is bad. Check the battery
voltage immediately, using the battery test
Testing the battery voltage
setting. See
5.
During the first 10 minutes of operation, the
energizer's remote control feature can be
activated. During this period, the large arrow on
the LCD display flashes to indicate this. This
occurs each time the energizer is switched on
when the energizer's remote control feature has
not been activated This is part of normal
operation.
The energizer has been switched off by a remote
control handset. If you think your energizer might
be being controlled by a neighbour's remote
control handset and you own a remote control
handset yourself, change your energizer's
address setting (see the remote control handset's
user manual). If you do not have a remote
control handset, take the energizer to an
authorised service centre to have the remote
control feature disabled.
on page
11

Publicidad

Tabla de contenido
loading

Tabla de contenido