If...
This means that...
The right arrow on the
During the first 10 minutes of operation, the
LCD is flashing...
energizer's remote control feature can be
activated. During this period, the large arrow
on the LCD display flashes to indicate this.
This occurs each time the energizer is
switched on when the energizer's remote
control feature has not been activated This is
part of normal operation.
The energizer is not
The energizer has been switched off by a
pulsing and the last
remote control handset. If you think your
green Indicator light is
energizer might be being controlled by a
flashing...
neighbour's remote control handset and you
own a remote control handset yourself,
change your energizer's address setting (see
the remote control handset's user manual).
If you do not have a remote control handset,
take the energizer to an authorised service
centre to have the remote control feature
disabled.
Product specifications
Power supply
Power consumption using a power adaptor
Current consumption using a 12 V rechargeable battery**
Battery Test
Slow Speed-Day/Fast Speed-Night
Fast Speed-Day/Slow Speed-Night
Half Output Power
Full Output Power
Pulse speed
Slow speed
Fast speed
Maximum output voltage
Maximum output energy
Maximum stored energy
*Currents stated are for a fully charged battery (12.6 V)
**Current consumption is affected by fence loading. If a fence is heavily loaded, the battery will only last half as long between charges.
Values are typical and normal production tolerances of ±5% should be allowed for.
Servicing
This energizer uses Double Insulation, where two systems of insulation are
provided instead of grounding. No equipment grounding means is
provided in the supply cord of a double-insulated energizer, nor should a
means for equipment grounding be added to the energizer. Servicing a
double-insulated energizer requires extreme care and knowledge of the
system and should only be done by qualified service personnel.
Replacement parts for a double-insulated energizer must be identical to
the parts they replace. A double-insulated energizer is marked with the
words DOUBLE INSULATION or DOUBLE INSULATED and/or the symbol
below.
12 V battery*,
or approved power adaptor 100-120 V or 100-240 V
Up to 19 W
Up to 950 mA
Up to 950 mA (day)
Up to 1300 mA (night) or
Up to 1125 mA (24 hour average)
Up to 1300 mA (day)
Up to 950 mA (night) or
Up to 1125 mA (24 hour average)
Up to 660 mA
Up to 1300 mA
2.5 seconds between pulses
1.5 seconds between pulses for light loads
1.8 seconds between pulses for heavy loads
9.9 kV
18 J at 50
24 J
11