4.2
RESET
If you want to return all the programmed parameters to their default settings, you should RESET the unit as follows:
Switch off the power supply.
Press and hold down the BLUE button and at the same time switch the power supply back on again.
S will appear fl ashing on the display. This indicates that you must repeat the self-teach cycle.
Press the YELLOW and BLUE buttons together for several seconds (for details see section 3.1.1).
5.1

OPERATING MODES

During the operating cycle the system handles the following signals:
STOP pulse and START pulse.
Closing safety photocell.
Opening safety device (photocell, safety edge ...).
Detection of any obstacle on the opening and closing strokes.
Operation of the automation functions in response to these signals depends on the operating mode selected.
The system operates in the automatic mode depending on the default settings. For instructions on changing the operating
mode, see sect. 7.1.
The next section describes the operating modes and the signal responses for each operating mode.
AUTOMATIC MODE (default mode) (0)
Starting with the gate closed, the complete operating cycle is as follows:
The START pulse is given.
After 3 seconds, wing 2 starts to open.
When both wings are opened as far as the mechanical stop, the gate will stay open for the programmed pause time.
Next, wing 2 will start to close.
After the preset delay time, wing 1 will start to close.
During the opening cycle, START pulses will be ignored and signals from closing photocells will also be ignored.
During the closing cycle, any START pulses or signals from
closing photocells will trigger reopening of the wings.
During the pause time with the gate open, the closing photocells
will keep the gate stopped and open until they are uncovered.
4-STEP MODE (1)
Starting with the gate closed, the complete operating
cycle is the same as that for the automatic mode.
If a START pulse is not given within the fi rst 3 seconds of
the opening pause
the gate will start to close automatically.
If a START pulse is given within the fi rst 3 seconds of
the pause time
the gate will stay locked in the open
position; to close the gate in this case you must give the
START pulse again.
SUPER AUTOMATIC MODE (2)
Starting with the gate closed, the complete operating
cycle is the same as that for the automatic mode.
The START pulse in any stage of a movement
reverses the direction of movement of the gate; it will be
possible to close the gate using the control.
SEMIAUTOMATIC MODE WITH STOP (3)
Starting with the gates closed:
START pulse the wings open and the gate stays stopped in
the open position. Another START pulse will close the gate.
The START pulse during opening stops the wings.
Another START pulse will close the wings.
The START pulse during closing
STEP-BY-STEP MODE (4)
Starting with the gates closed:
START pulse the wings open and the gate stays stopped in
the open position. Another START pulse will close the gate.
The START pulse during opening stops the wings.
Another START pulse will close the wings.
The START pulse during closing stops the wings.
Another START pulse will reopen the wings.
RSK24-2000/2500
Wing 1 starts to open.
reopens the wings.
- 21 -
CONTROL UNIT
Automatic logic:
1
gate closed
2
gate open
1
3
gate opening
pause time
4
1
The letter
Fig.6
START pulse
2
3"
gate closing
2