2. INSTALLATION

CAUTION -
The product must only be installed by qualified servicing and/or installation
personnel.
CAUTION -
The electrical system must comply with the current regulations in the
country where the product is installed.
CAUTION -
Always turn the power off before opening the box. Make sure the
earthing system is efficient and connected to the special terminals.

2.1 PREPARATION

This device can be installed inside or outside the motor.
CAUTION -
The installation inside the motor is only permitted if expressly foreseen
by the manufacturer.
In the case of outside installation, prepare the tools required to fix the device to the wall
and for the electrical connections as well as the following tools:
1. Ø 6 mm expansion anchors
2. PG16 skintop-type cable straps
3. One multipolar switch with 3mm minimum contact opening
4. One emergency pushbutton
5. Approved cables for outdoor use with minimum cross-section of 0.75 mm

2.2 ASSEMBLY

It is not necessary to drill any holes to fit the device.
1.
Fix the device at least 30 cm above the floor using the fixing holes on the plastic box.
2.
Insert the connecting cables through the stamped holes at the bottom of the box and
the cable straps as indicated.
3.
Fit the omnipolar switch upstream of the device.
4.
Fit an emergency pushbutton in a position where the automation system can be seen
and so that the power supply to the system can be completely cut-off.
5.
Use 1.5 mm² section cables for the motor power supply and 0.75 mm² section cables
for 24 VDC devices.

2.3 ELECTRICAL CONNECTIONS

Make the electrical connections as indicated in the diagram alongside.
CAUTION-
Before any connection, turn the power off.
CAUTION -
Only qualified electrical installers should make the electrical system
consistent with the electrical code of the installation country using
certified materials.
CAUTION -
Make sure the earthing system is efficient and connected to the special
terminals.
ENGLISH
K1
1
- 24 V Common
2
Start
3
Stop
4
Photocell
5
Closing with Dead Man input
6
Open limit switch
7
Close limit switch
8
-
9
+
2
2
and 1.5 mm
10
-
11
K2
Opening
12
Closing
13
Common
14
15
16
If the terminal safety contacts 2 and 4 (stop input) and terminals 2 and 5
(photocell input) are not used, jumpers must be fitted.
The function of terminal input 6 depends on the setting of the dip-switches or
the logic selected and switches from N.O to N.C.
+ 24 V
Max. 3 W warning light
LED
Capacitor
M
Connect motor earth
to the device earth
connection
Neutral
Protect with a 6A differential switch -
overload 30 mA
Phase
NC contact = Opening safety
device in the following
modes: Automatic,
Semiautomatic with stop and
Automatic with stop
230V flashing unit.
Caution: preflashing
not available