Receiver Programming (Only For T22) - Aprimatic T22 Instrucciones Para La Instalación

Ocultar thumbs Ver también para T22:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

• During the pause time or when the photocells are activated, the device will remain in
pause until the photocells are cleared.
SEMIAUTOMATIC MODE WITH STOP - If you select this operating mode when the gate
is closed, when a start pulse is given, the gate opens as far as the opening limit switch.
If another start pulse is given during opening, the gate stops immediately until another
start pulse is given: this closes the automation. A start pulse sent during closing re-opens
the gate.
AUTOMATIC MODE WITH STOP
Start pulse when gate is closed: opens the gate.
Start pulse during gate opening: stops the gate and automatically starts pause time.
Start pulse during gate pause: starts immediate pre-flashing and then gate closing.
Start pulse during gate closing: changes the gate travel direction.
DEAD MAN MODE - This operating mode requires the physical presence of a human
operator, who opens and closes the gate and the input of terminal 6 is used as the closing
input. To open the gate, press the start pushbutton and hold it down (opening input). When
the pushbutton is released, the gate is blocked. To close the gate, press the close
pushbutton and hold it down; if the photocells are activated, the device blocks the gate
travel. In this case, the operator must release the pushbuttons and press either close or
open. This is also the case if the two pushbuttons are pressed at the same time.
DIP-SWITCH SW1
S1
S2
OPERATING MODE
ON
ON
Standard Automatic
OFF
ON
Semi-automatic with Stop
ON
OFF
Automatic with Stop
OFF
OFF
Dead Man
DIP SWITCH 3 (PAUSE PHOTOCELL) - This SWITCH is used to select the pause
photocell function when the automatic functioning mode is enabled. When the SWITCH is
in the ON position, if the photocell beam is interrupted and cleared with the automation in
pause, the device will command pre-flashing for 3 seconds and will then close the gate,
even if the pause time has not been concluded. When the SWITCH is in the OFF position,
the gate will only close when the set pause time expires.
ENGLISH
S3
PHOTOCELL FUNCTION
ON
Immediate re-closure
OFF
Pause time zero-ing
S4
PRE-FLASHING
ON
Enabled
OFF
Disabled
DIP-SWITCH 4 (PRE-FLASHING) - This SWITCH is used to enable or disable pre-
flashing. It is possible for both the opening and closing stages. If the function is enabled,
before the automation opens or closes, there will be a signal for 3 seconds and the warning
light and flashing light will come ON before the gates move.

3.4 RECEIVER PROGRAMMING (ONLY FOR T22)

JP5-8
(ENABLING BUTTON) - Using the jumpers JP5-8, you can select which receiver
output channel and, therefore, which remote control button, will enable the output signal.
This selection is made by closing just one of the jumpers present, following the scheme
indicated below:
Ch4
JP5 – Channel 1 - Button 1
JP8
JP6 – Channel 2 - Button 2
Ch3
JP7 – Channel 3 - Button 3
JP7
OUT RX
JP8 – Channel 4 - Button 4.
Ch2
JP6
WARNING: Only close one jumper or you
Ch1
risk breaking the unit.
JP5
JP3-4
(ENABLING BUTTON ROW) - The receivers may be used with 2-, 4- or 14-
button remote controls. If you use it with a 14-button remote control, you can use the
jumpers JP3 and JP4 to define which row of buttons the receiver must respond to,
following the scheme indicated below:
JP3 – JP4 open: row 1 (Buttons 1-4)
JP3 closed: row 2 (Buttons 5-8)
JP4 closed: row 3 (Buttons 9-12)
JP3 – JP4 closed: row 4 (Buttons 13-14).
JP3
O F F
ON
JP4
O F F
O F F
INFORMATION: The receiver may also receive commands from 2- and 4-button remote
controls (TR2 and TR4) but only if JP3 and JP4 are left open (first configuration above).
JP1-2
(OUTPUT FUNCTIONING LOGIC) - The functioning modes of the output channels
3 and 4 can be selected using the jumpers JP1 and JP2, following the scheme indicated
below. The output channels 1 and 2 operate, in any case, with a pulse output which has a
duration of 1 second.
O F F
ON
ON
ON
7