Manual Disabling Of The Detector; Indication Of Faults; Power Supply Fault - hager TG 500A Manual De Instalación

Detector de humo
Ocultar thumbs Ver también para TG 500A:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 64

Manual disabling of the detector

It is possible to disable the detector for a 15 min.
period:
• Prior to activities likely to produce dust (sweeping of
a dusty room, of a chimney...) and cause unwanted
alarm activation,
• To stop alarm in the event of detection of non-
dangerous smoke.
In order to disable the detector, press the test key until
the 1st beep sounds or until the detector stops its
built-in audible alarm. The indicator signalling the state
of the detector flickers every 2 sec.
After the 15 min. disable period has passed or after
a manual test, the detector is set back automatically
into normal operation with the detector state indicator
flickering every 10 s.

Indication of faults

Power supply fault:

Detector at the source of the fault indication
TG 500A/TG 500B
the unit flickers once
every 5 sec.
the unit emits 2 fast beeps every 60 sec
If the sound indication of the power supply failure occurs at an inappropriate time, it is
possible to postpone its occurrence for an 8-hour delay over a maximum 7-day period by
pressing the test key until the 1st beep is emitted.
This is the time period available for replacing the battery.
TG 501A
-
32
For the 15 min. disable period,
the detector will not detect
any smoke, nor emit any
audible alarm.
In the case of an installation in
network and of a non-dange-
rous smoke detection, it is
obligatory to inhibit the
detector at the origin of detec-
tion (led red twinkling) to stop
the ringing.
After the power supply fault
has occurred, the detector will
operate normally for a 30-day
period. However is advisable
to replace the battery as soon
as possible.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Tg 500alTg 500bTg 501aTg 501al

Tabla de contenido