ENGLISH
DMX Channels Chart When ILDA is connected
CHANNEL
Grating
Rotation
Grating Effect
#4 ILDA CONTROL:
This laser can be controlled by any PC equipped with ILDA compatible software + hardware. As soon as
the ILDA-input (17) of the laser is connected with an ILDA compatible controller, it will automatically switch
to ILDA control mode. From this moment on the laser will be completely controlled by the ILDA software:
the possibilities of the ILDA software will determine what you can do or not...
ILDA soft- and hardware are available from several independent suppliers. Some possible choices are:
-
PHOENIX software (www.bocatec.de)
-
PANGOLIN software (www.pangolin.com)
And many other, up to you and your finances to see what is best for your needs ...
-
MAINTENANCE
Make sure the area below the installation place is free from unwanted persons during servicing.
Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.
The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit's optics.
Clean with a soft cloth using normal glass cleaning products.
Always dry the parts carefully.
Clean the external optics at least once every 30 days.
Clean the internal optics at least every 90 days.
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!
BRITEQ
®
VALUE
000-004
CH1
005-127
128-133
134-255
000-031
032-063
064-095
CH2
096-127
128-159
160-191
192-223
224-255
DESCRIPTION
No grating rotating
Clockwise grating rotating
No grating rotating
Anticlockwise grating rotating
Laser 3D Effect
Scanned Beam Effect (Pattern Effect)
Laser Lumia Effect
Scanned Beam Effect (Pattern Effect)
Burst Grating Effect
Scanned Beam Effect (Pattern Effect)
Laser Universal Effect
Scanned Beam Effect (Pattern Effect)
12/68
USER MANUAL
SPECTRA 3D LASER