terminals and must have a contact separation at all its poles, which provides total discon-
nection under conditions of Category III overvoltage. The fan must be directly connected
to a properly protected installation circuit (magnetothermal differential switch with the
adequate size for the fan's consumption and technical specifications). Only use the fan's
control to turn it on or stop it.
6. It is recommended to not use these types of fans along with gas installations simulta-
neously in the same room.
7. The fan must be not be moving and must have come to a complete stop before changing
its direction of rotation. This will prevent damage to its motor and to the control unit, when
applicable.
8. Do not insert anything that could hit the fan's blades into its pathway while it is moving,
as this could cause damage to people, can damage the blades, and can offset the balance of the
unit, causing vibrations and wobbling.
EN
9. After installing the fan, ensure that all fastenings are secure and tightened in order to
avoid any noise caused by loose elements.
10. Due to the fan's movement, certain fastenings may become loose. Check all fastenings
twice per year at a minimum in order to ensure that they are sufficiently tight. If necessary,
they must be retightened.
11. If the power cord is damaged, it must be replaced by the manufacturer, its after-sales
service or similar qualified personnel in order to avoid any malfunction.
12. The light source of this luminaire must only be replaced by the manufacturer, its technical
service or a qualified person.
Note: The important warnings and instructions indicated in this manual are not guaranteed to
cover all possible conditions and situations that may occur. It must be understood that common
sense, precaution, and care are factors that cannot be included in all products. These factors
can and must only be provided by the user who maintains and enjoys this fan.
Device technical spectifications
Nominal voltage and frequency
Protection category
Protection index
Word temperature
Maximun ceiling slope on which it can be installed
Speed
Fan power (W)
Fan RPM
Fan airflow (m
Noise level (dB)
12
/min)
3
220-240V~AC 50Hz
-20 ↔ 40ºC
1
2
3
4
4.5
5.3
6.7
7.9
650 720 800 880 950
48
54
65
82 130
15
18
23
26
Clase I
IP20
15º
5
9.7
30