Operation With Different Types Of Gas - Lamborghini Caloreclima EM 16/M-E Manual De Instrucciones

Ocultar thumbs Ver también para EM 16/M-E:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

OPERATION WITH DIFFERENT TYPES OF GAS

CONVERSION FROM NATURAL GAS TO B/P
A specific burner is not previewed. Should you wish to adapt a burner to a certain type of gaseous fuel, bear in mind the
following:
- since different conditions ca arise the use of B/P it is necessary to eplace head assembly included in the supplied KIT.
EM 16/M-E
D
E
F
Loosen the screws D, remove the diffuser ring E and replace it
with another ring of type F, which differs from type E in that there
are less gas outflow holes.
EM 26/M-E
H
G
H
Remove the electrodes G from the head assembly. Loosen the
screws H and replace the head assembly I. Fit the electrodes
as per the instructions given in the manual.
I
PRESSURE CURVES - B/P GAS DELIVERY
EM 16/M-E
EM 26/M-E
Thermal output
Thermal output
Legend
Pi Inlet pressure (combustion head + gas train)
Pt Pressure at combustion head
- 45
-

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Em 26/m-e

Tabla de contenido