Menu <–> Selection
press the
5 5 . . 3 3 . . 4 4 . . 3 3 C C h h a a n n g g i i n n g g t t h h e e s s c c a a l l i i n n g g s s l l o o p p e e
Menu <–> Selection
press the
5 5 . . 4 4 S S e e t t t t i i n n g g t t h h e e S S c c a a l l i i n n g g S S l l o o p p e e
At least two points (2 pairs of values) are
required for the start point and end point of
the scaling slope. This slope can be rising
or falling. A maximum of 24 scaling points
can be used.
H H o o w w e e v v e e r r i i t t s s h h o o u u l l d d b b e e n n o o t t e e d d t t h h a a t t i i n n a a l l l l
c c a a s s e e s s , , w w h h e e t t h h e e r r t t h h e e s s l l o o p p e e r r i i s s e e s s o o r r f f a a l l l l s s , , t t h h e e
v v a a l l u u e e s s t t h h a a t t a a r r e e i i n n p p u u t t t t e e d d ( ( I I n n p p . . 0 0 1 1 ... ... I I n n P P . . 2 2 4 4 ) )
m m u u s s t t i i n n c c r r e e a a s s e e s s e e q q u u e e n n t t i i a a l l l l y y . .
Page 18
Example: 80.000
Select digit
Set digit
keys to accept the selection
use the current scaling slope
5.5 Monitoring parameter
Setting the scaling slope
5.4 Monitoring parameter
keys to accept the selection
When the input signal exceeds the value
set here, than
O O v v e e r r - - r r a a n n g g e e : : When the value exceeds
109 mV then
21
18
The scaling slope must lie within the limits
of the input and display ranges. The first
and last points can lie on the limits.
is displayed.