Multiple Products Operate In Group; Wiring Diagram; Operation Methods - Panasonic FY-3009U1 Instrucciones De Instalación Y De Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 54

Multiple products operate in group

WARNING
Please select the switch of whose
capacity has 1.2 ~ 1.5 times total current,
when multiple products operate.
Earth leakage breaker protector
should be equipped, otherwise it may
cause an electrical shock.
The number of interlocking operation
is not more than 6.

Wiring diagram

Operation methods

Operation of Control panel
Representative model
1
Start to operate
2
Select the mode of operation
Red
Capacitor
Orange
Black
Black
Switch
White(H)
White
Yellow(L) Yellow
(Contact Point Separate Distance Over 3mm)
OFF LOW
Press "HI" or "LO" button to start the product as
shown in left figure.
Press "HI" button if high air velocity is required.
Press "LO" button if quiet and low velocity is
required.
Please purchase necessary parts
following with local electrical
requirements, except the power
supply cord.
Power supply cord
Green/Yellow
Blue
Brown
Double Pole Switch
Customer Provide
HIGH